Performance Data
OAU-SVX01K-EN
63
Motor RPM, Standard–Oversized
1750–3500
1750–3500
1750–3500
Motor Frame Size, Standard–Oversized
Varies
Varies
Varies
Filters
Type Furnished
Refer to
in
Refer to
in
in
Number Size Recommended
Refrigerant Charge, lb of R-410A
Downflow
See Nameplate
See Nameplate
See Nameplate
Table 14. OAND general data—cooling 30–40 tons high efficiency (continued)
30 Tons Downflow
35 Tons Downflow
40 Tons Downflow
OAND360A
OAND420A
OAND480A
Table 15. OAND general data—cooling 45–54 tons high efficiency
45 Tons Downflow
50 Tons Downflow
54 Tons Downflow
OAND540A
OAND600A
OAND648A
Cooling Performance
Gross Cooling Capacity, Btu (kW)
553,176 (162.12)
614,640 (180.13)
663,811 (194.54)
Nominal cfm (m
3
/h)
5625–11250
(9557–19114)
6250–12500
(10619–21238)
6750–13500
(11468–22937)
Compressor
Number
3
4
4
Type
Scroll
Scroll
Scroll
Outdoor Coil
Type
High Performance
High Performance
High Performance
Tube Size—OD, in. (mm)
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
Face Area, ft
2
(m
2
)
63 (5.85
63 (5.85
63 (5.85
Rows
4
4
4
FPI
12
12
12
Indoor Coil
Type
High Performance
High Performance
High Performance
Tube Size—OD, in. (mm)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
Face Area, ft
2
(m
2
)
29 (2.69)
29 (2.69)
29 (2.69)
Rows
6
6
6
FPI
12
12
12
Refrigerant Control
TXV
TXV
TXV
Drain Connection Size, in. (mm)
1-1/4 (32)
1-1/4 (32)
1-1/4 (32)
Outdoor Fan
Type
Propeller
Propeller
Propeller
Number Used
4
4
4
Diameter, in. (mm)
24 (609.6)
24 (609.6)
24 (609.6)
Drive Type
Direct
Direct
Direct
No. Speeds
1
1
1
CFM (m
3
/h)
26,000 (44,174)
26,000 (44,174)
26,000 (44,174)
Number Motors
4
4
4
Motor HP (kW), per motor
1.0 (0.75)
1.0 (0.75)
1.0 (0.75)
Motor RPM
1140
1140
1140
Indoor Fan
Type
Backward Inclined
Backward Inclined
Backward Inclined
Number Used
1 or 2
1 or 2
1 or 2
Diameter
Varies
Varies
Varies
Drive Type
Direct Drive
Direct Drive
Direct Drive
Number Motors
1 or 2
1 or 2
1 or 2
Motor HP (kW), Standard–Oversized
2.0–15 (1.49–11.19)
3.0–15 (2.24–11.19)
3.0–15 (2.24–11.19)
Motor RPM, Standard–Oversized
1750–3500
1750–3500
1750–3500