Table 11. OAKD general data—cooling 22–30 tons high efficiency
22 Tons Downflow
25 Tons Downflow
30 Tons Downflow
OAKD264A
OAKD300A
OAKD360A
Cooling Performance
Gross Cooling Capacity, Btu (kW)
270,442 (79.26)
307,320 (90.07)
368,784 (108.08)
Nominal cfm (m
3
/h)
2750–5500
(4692–9345)
3125–6250
(5309–10619)
3750–7500
(6371–12743)
Compressor
Number
2
2
2
Type
Scroll
Scroll
Scroll
Outdoor Coil
Type
High Performance
High Performance
High Performance
Tube Size—OD, in. (mm)
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
Face Area, ft
2
(m
2
)
38 (3.53)
38 (3.53)
38 (3.53)
Rows
3
3
3
FPI
12
12
12
Indoor Coil
Type
High Performance
High Performance
High Performance
Tube Size—OD, in. (mm)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
Face Area, ft
2
(m
2
)
15 (1.39)
20 (1.86)
20 (1.86)
Rows
6
6
6
FPI
12
12
12
Refrigerant Control
TXV
TXV
TXV
Drain Connection Size, in. (mm)
1 (25)
1 (25)
1 (25)
Outdoor Fan
Type
Propeller
Propeller
Propeller
Number Used
3
3
3
Diameter, in. (mm)
24 (609.6)
24 (609.6)
24 (609.6)
Drive Type
Direct
Direct
Direct
No. Speeds
1
1
1
CFM (m
3
/h)
19,500 (33,131)
19,500 (33,131)
19,500 (33,131)
Number Motors
3
Motor HP (kW), per motor
1.0 (0.75)
1.0 (0.75)
1.0 (0.75)
Motor RPM
1140
1140
1140
Indoor Fan
Type
Backward Inclined
Backward Inclined
Backward Inclined
Number Used
1
1
1
Diameter
Varies
Varies
Varies
Drive Type
Direct Drive
Direct Drive
Direct Drive
Number Motors
1
1
1
Motor HP (kW), Standard–Oversized
1.0–7.5 (0.75–5.6)
1.0–15.0 (0.75–11.19)
1.0–15.0 (0.75–11.19)
Motor RPM, Standard–Oversized
1750–3500
1750–3500
1750–3500
Motor Frame Size, Standard–Oversized
Varies
Varies
Varies
Filters
Type Furnished
in
in
in
Number Size Recommended
Refrigerant Charge, lb of R-410A
Downflow
See Nameplate
See Nameplate
See Nameplate
Performance Data
OAU-SVX01K-EN
59