7
18-GJ11D1-2
Ballast assembly installation
STEP 10
. Disconnect the high voltage wiring harness on the right
side of the indoor coil.
IMPORTANT: For easy of installation, the Power Plugs must be con-
nected before installing the ballast as
sembly in the unit.
IMPORTANT: The ballast assembly is provided with aggressive adhe-
sive on back. The adhesive has a peel-off liner. Do not remove the liner
until proper mounting locations within the unit have been confirmed.
NOTE: Use isopropyl alcohol to thoroughly clean and dry the surfaces
of the inside coil compartment wall in the areas where the ballast as-
sembly will be permanently mounted.
▲
WARNING
!
HAZARDOUS VOLTAGE!
Multiple power sources may
be present. Disconnect all electrical power, including remote
disconnects, before servicing. Follow proper lockout/tagout
procedures to ensure the power can not be inadvertently
energized. Failure to disconnect power before servicing could
result in death or serious injury.
Scribe Line
Содержание BAYUVCLK001
Страница 15: ...15 18 GJ11D1 2 Wiring Diagram...