STEP 22

.  There are two yellow control wires in the UV accessory 

that are only used with Series 8 air handlers. Connect these two 
wires to the two yellow UV Light wires in Series 8 air handlers 
as shown using the wire nuts provided. (Refer to air handler 
wiring diagram .)

For all other air handlers stow these wires securely and leave them 

unconnected.

NOTE:  A BAYCC24VK01 can be installed for Series 8 Air Han-
dlers to extend the life of the lamp.  This accessory kit will disable 
the lamp during the heating season (kit is purchased separately).

STEP 23

.  Use the provided cable ties to secure all wires

STEP 24

.  Apply wiring diagram label to the inside of the coil com-

partment panel.

IMPORTANT:  Make sure all wires are secured completely behind 
the crossbar and below the coil to prevent wire damage when coil 
panel is replaced.

STEP 25

.  Apply UV Hazard warning label to the outside of the coil 

compartment panel.  Place panels back on air handler.

3.  Scribe

 Horizon

tal Line

 

Locating Bottom of La

mp

 

Brac

ket

-

Br

-

Series 8 Air Handler Only

Содержание BAYUVCLK001

Страница 1: ...ep tible to deterioration by the UV C lamp shall be shielded from direct exposure to the light This kit was designed with this consideration and the reflectors must be in place In addition UV C radiat...

Страница 2: ...h and rubbing alcohol or glass cleaner after handling WARNING Hazardous Voltage and Exposure to Ultraviolet Radiation This product contains components that emit high intensity ultraviolet UV C radiati...

Страница 3: ...not remove the liner until these items have been placed into unit and proper mounting locations within the unit have been confirmed IMPORTANT The two lamp brackets are not symmetrical One is marked Ri...

Страница 4: ...Bkt Upflow Horizontal Right Downflow Horizontal Left Left Bkt Ballast Right Bkt Left Bkt Ballast Right Bkt Left Bkt Ballast Right Bkt Left Bkt Ballast UV Lamp Brackets and Ballast locations for Air H...

Страница 5: ...Measure7 5inchesabovethecrossbarandmake a mark on the inside of the air handler cabinet use a screwdriver or other metal object to scribe line STEP 4 Draw a level line to the back of the air handler c...

Страница 6: ...ompartment inner wall STEP 8 Cut the cable tie on the left side lamp bracket assembly Slide the lamp and reflector assembly out of the lamp bracket as shown STEP 9 Measure 7 5 inches above the cross b...

Страница 7: ...liner until proper mounting locations within the unit have been confirmed NOTE Use isopropyl alcohol to thoroughly clean and dry the surfaces of the inside coil compartment wall in the areas where th...

Страница 8: ...lugs The tie prevents strain on the splices STEP 12 Connect the ballast assembly in series with the high voltage leads Ballast assembly with power plugs Unconnected From Blower Compartment From Blower...

Страница 9: ...g on the air handler cross bar The notch of the ballast assembly will slide into the ridge of the air handler Ensure a solid fit before removing peel off liner and exposing the adhesive back Note Be c...

Страница 10: ...ng UV Lamp wiring connections NOTE If the coil was removed before installation replace the coil before continuing with the kit installation STEP 16 Install the left and right side lamps and reflectors...

Страница 11: ...cure the grounding wire in place Then place a second factory supplied nut onto the stud and tighten in place also STEP 19 Support the lamp and place the pin connector on the lamp The connector is posi...

Страница 12: ...ers to extend the life of the lamp This accessory kit will disable the lamp during the heating season kit is purchased separately STEP 23 Use the provided cable ties to secure all wires STEP 24 Apply...

Страница 13: ...V appliance upon opening or removal WARNING STEP 26 Remove the heater panel STEP 27 Set the system comfort control to OFF and restore power STEP 28 Use an ammeter to check for current flow on the high...

Страница 14: ...the unit 2 Open the coil panel 3 Cut the cable tie and remove the plug from the lamp 4 Wearing soft cloth gloves and safety glasses use two hands and firmly grasp the lamp at nearest end 5 Remove the...

Страница 15: ...15 18 GJ11D1 2 Wiring Diagram...

Страница 16: ...ne 6200 Troup Highway Tyler TX 75707 12 10 Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specifications without noti...