background image

13

 

18-GJ11D1-2

Testing for Proper Operation

SAFETY HAZARD! 

This information is for use by individu-

als having adequate backgrounds of electrical and mechanical 
experience. Any attempt to repair a central air conditioning 
product may result in personal injury and/or property dam-
age. The manufacturer or seller cannot be responsible for the 
interpretation of this information, nor can it assume any liability 
in connection with its use.

WARNING

!

PERSONAL INJURY HAZARD!

 

Disconnect input 

power before beginning installation. Professional installation 
required per NEC standards. The power supply to this ultravio-
let appliance must be disconnected before opening or servicing 
the unit. Any access panels or doors, within sight of the UV 
lamps, must be interlocked so as to disconnect power to the 
UV appliance upon opening or removal.

WARNING

!

STEP 26

.  Remove the heater panel.

STEP  27

.  Set  the  system  comfort  control  to  OFF  and  restore 

power.

STEP 28

. Use an ammeter to check for current flow on the high volt-

age wires entering the air handler.  The lamps should generate 
approximately 0.2 amps of current when energized.

 The Series 8 air handler with a BAYCC24VK01 kit will energize the 

lamps when the system is in the cooling mode. The lamps will 
remain energized for 48 hours after then end of cooling mode.  
This minimizes the short cycling of the lamps.

Step 29.

 Replace the heater panel and restore the system comfort 

control to its original setting.

PERSONAL INJURY HAZARD! 

UV-C can be harmful 

to unprotected eyes.  Do not troubleshoot the lamps by sight.

WARNING

!

ELECTRICAL HAZARD! 

The ballast produces a very 

high voltage.  Checking for voltage output is likely to cause 
damage to the meter.  Failure to follow this warning could result 
in property damage, serious personal injury, or death. 

WARNING

!

Содержание BAYUVCLK001

Страница 1: ...ep tible to deterioration by the UV C lamp shall be shielded from direct exposure to the light This kit was designed with this consideration and the reflectors must be in place In addition UV C radiat...

Страница 2: ...h and rubbing alcohol or glass cleaner after handling WARNING Hazardous Voltage and Exposure to Ultraviolet Radiation This product contains components that emit high intensity ultraviolet UV C radiati...

Страница 3: ...not remove the liner until these items have been placed into unit and proper mounting locations within the unit have been confirmed IMPORTANT The two lamp brackets are not symmetrical One is marked Ri...

Страница 4: ...Bkt Upflow Horizontal Right Downflow Horizontal Left Left Bkt Ballast Right Bkt Left Bkt Ballast Right Bkt Left Bkt Ballast Right Bkt Left Bkt Ballast UV Lamp Brackets and Ballast locations for Air H...

Страница 5: ...Measure7 5inchesabovethecrossbarandmake a mark on the inside of the air handler cabinet use a screwdriver or other metal object to scribe line STEP 4 Draw a level line to the back of the air handler c...

Страница 6: ...ompartment inner wall STEP 8 Cut the cable tie on the left side lamp bracket assembly Slide the lamp and reflector assembly out of the lamp bracket as shown STEP 9 Measure 7 5 inches above the cross b...

Страница 7: ...liner until proper mounting locations within the unit have been confirmed NOTE Use isopropyl alcohol to thoroughly clean and dry the surfaces of the inside coil compartment wall in the areas where th...

Страница 8: ...lugs The tie prevents strain on the splices STEP 12 Connect the ballast assembly in series with the high voltage leads Ballast assembly with power plugs Unconnected From Blower Compartment From Blower...

Страница 9: ...g on the air handler cross bar The notch of the ballast assembly will slide into the ridge of the air handler Ensure a solid fit before removing peel off liner and exposing the adhesive back Note Be c...

Страница 10: ...ng UV Lamp wiring connections NOTE If the coil was removed before installation replace the coil before continuing with the kit installation STEP 16 Install the left and right side lamps and reflectors...

Страница 11: ...cure the grounding wire in place Then place a second factory supplied nut onto the stud and tighten in place also STEP 19 Support the lamp and place the pin connector on the lamp The connector is posi...

Страница 12: ...ers to extend the life of the lamp This accessory kit will disable the lamp during the heating season kit is purchased separately STEP 23 Use the provided cable ties to secure all wires STEP 24 Apply...

Страница 13: ...V appliance upon opening or removal WARNING STEP 26 Remove the heater panel STEP 27 Set the system comfort control to OFF and restore power STEP 28 Use an ammeter to check for current flow on the high...

Страница 14: ...the unit 2 Open the coil panel 3 Cut the cable tie and remove the plug from the lamp 4 Wearing soft cloth gloves and safety glasses use two hands and firmly grasp the lamp at nearest end 5 Remove the...

Страница 15: ...15 18 GJ11D1 2 Wiring Diagram...

Страница 16: ...ne 6200 Troup Highway Tyler TX 75707 12 10 Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specifications without noti...

Отзывы: