6.21
Stepper Current Settings (Silent Drivers)
Notice that jumper settings have changed (all removed except Z
–
see below). Procedure is as for old
stepper drivers, values are changed as follow:
•
Readout on E0/E1/E2 = 0.9 V
•
Readout on X / Y = 1,4 V
•
Readout on Z = 1.15 V
Figure 6.21.1 Silent Driver Jumper Settings