Operators Manual - Pentruder Modular Drilling system
4
•
The operator should have good supervision over the drill system and inform passing
persons about possible risks.
•
Unauthorized persons shall not be within the risk area (the area around the drill unit).
•
Always lift the drill unit ergonomically correct. The Pentpak is not provided with hooks
for lifting. Should this unit need to be lifted with a crane, this should only be done after
permission and instructions have been given by a person responsible for safety on the
site. Contact your sales agent for instructions on how the lifting can be done in the best
way.
•
The base plate must always be securely anchored to perform safe drilling.
•
Never run the drill unit without water cooling. The seals are quickly worn and water leak
can occur. Should the cooling water seeze to function, stop the machine immediately.
•
Before drilling is commenced all persons involved must know how the emergency stop
button is working.
•
Remember always to cover drilled holes so that no person falls down and hurts
himself.
•
Only connect the power pack to the Pentruder drill system or such equipment, which
has been manufactured or approved by Tractive AB.