7.15 Object 6010h: Preset_Values
The object defines the position values for the preset function and is used to set the
measuring system value of the supported channels to any position value within the
range of 0 to measuring length in steps. The preset function is executed using
Object 2010h: Preset_Release, see page 92.
Index
0x6010
Object type
Array
Name
Preset_Values
Data type
UNSIGNED32
Category
Optional
Preset value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
Sub-Index
000
Description
Number of available channels
Access
CONST
PDO mapping
no
Default value
3
Value range
0x01…0x03
Sub-Index
001…003
Description
Preset_Value1 to 3, Preset value channel 1 to 3
Category
Optional
Data type
UNSIGNED32
Access
rw
PDO mapping
no
Default value
0
Value range
0…FF FF FF FF
Magnet 1 to 3:
Value within the range of 0 to measuring length in steps