7.9 Object 2011h: Reference_Zero_To_Preset
With this object for each magnet the difference of the desired Preset value to the
physical zero point of the measuring system after a Preset execution is indicated.
Index
0x2011
Object type
Array
Name
Reference_Zero_To_Preset
Data type
UNSIGNED32
Category
Optional
Sub-Index
000
Description
Number of entries
Access
CONST
PDO mapping
no
Default value
3
Value range
0x01…0x03
Sub-Index
001…003
Description
Reference1 to 3, Offset to absolute zero point 1. to 3. magnet
Category
Optional
Data type
UNSIGNED32
Access
ro
PDO mapping
no
Default value
0
Value range
0…0xFF FF FF FF