![TR-Electronic LMPI-46 Скачать руководство пользователя страница 88](http://html1.mh-extra.com/html/tr-electronic/lmpi-46/lmpi-46_user-manual_1146712088.webp)
Manufacturer and Profile Specific Objects (CiA DS-406)
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 88 of 111
TR - ELA - BA - DGB - 0029 - 00
08/29/2018
7.1.2 Reference-Reversal
Index
0x2000
Object type
VAR
Name
Mode
Data type
UNSIGNED8
Category
Optional
Value range
Bit 0 = 1: Reference-Reversal
Access
rw
Default value
0
PDO mapping
no
In Mode
Reference-Reversal
the physical zero point of the measuring system is at
point 2 and the upper limit of range is at point 1, if in Object 6000h:
Operating_Parameter the bits 2
2
and 2
3
are set to 1 (reversal of the counting
direction).
Definition:
● Setting a Preset value refers to the respective magnet
● Counting method of the magnets: Outgoing from point 1, decreasing
Figure 12: Mode "Reference-Reversal"