![TR-Electronic LE-200 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/tr-electronic/le-200/le-200_user-manual_1146676018.webp)
Commissioning / Installation
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 18 of 37
TR - ELE - BA - GB - 0008 - 06
14.12.2007
5.1.2.2 Remote OUT
Pin 6
GND,
reference potential Remote OUT
Pin 11
DO2 inverted
Pin 12
DO2
Pin 13
DI2 inverted
Pin 14
DI2
1 2 3
4 5
6
7 8
9 10
11 12 13 14
15 16 17 18 19 20
5.1.2.3 Identification of following slaves
For the subsequent node to be detected, between PIN 5 "RBST inverted" and PIN 4
"GND" a jumper must be inserted.
Pin 4
GND,
reference potential for RBST
Pin 5
RBST
inverted
1 2 3
4 5
6 7 8
9 10
11 12 13 14 15 16 17 18 19 20
5.1.3 Switching input / Switching output
The programming of the switching input /switching output is carried out either directly
via the bus, or via the PC software "TRWinProg".
Functions of the switching input:
-
Preset, - Switch off laser diode, - Failure quit
Functions of the switching output:
-
Temperature- , - Intensity- , - Hardware-Fail-Output, - every fail
-
Speed-check, Plausibility measured value, Switching output position
Pin 1
GND, reference potential pin 2
Pin 2
Switching
output
Pin 3
Switching
input
1 2 3
4 5 6
7 8
9 10 11 12 13 14
15 16 17 18 19 20
5.1.4 RS485 - programming interface
The RS485 programming interface was developed mainly only as service interface for
the technician.
Primarily therefore the programming possibilities via the Interbus-S should be used.
Via the PC software "TRWinProg" and a PC adapter the connection to the laser
measuring device is established. More informations see page 19 or in the TRWinProg
software manual.
Pin 9
RS485–
Pin 10
RS485+
1 2 3
4 5 6
7 8
9 10
11 12 13 14