Technical data
TR-Electronic GmbH 2019, All Rights Reserved
Printed in the Federal Republic of Germany
Page 22 of 47
TR-ECE-BA-GB-0138 v04
08/20/2021
4.5.2 Ex-labeling, dust
II
2D
Ex
tb
III
C
T80°C
…T130°C
Db
EPL (IEC/CENELEC)
max. surface temperature
Explosion group (IEC/CENELEC)
Group (IEC/CENELEC)
Ignition protection type (IEC/CENELEC)
Labeling (IEC/CENELEC)
Device category (ATEX)
Device group (ATEX)
Ex-labeling (ATEX)
Device group .........................................................
II
: on the surface applications
Device category ....................................................
2D
: Zone 21
adequate safety in case of predictable failures
Ignition protection type ........................................
tb
: Protection by enclosure
Ex-Atmosphere is kept away from the ignition source
Group .....................................................................
III
: potentially dust-explosive areas
Explosion group ...................................................
C
: Type of dust: conductive dust
Temperature ..........................................................
max. enclosure surface-temperature
T130°C ...................................................................
130 °C
T95°C .....................................................................
95 °C
T80°C .....................................................................
80 °C
EPL (
Device protection level
) .................................
D
“b” (Zone 21):
adequate safety in case of predictable failures