BEFORE CALLING FOR SERVICE
The following are not defects.
A hissing noise or hol-
low sound:
Ö
This sound is generated from the
refrigerant flowing within pipes.
A squeaking noise:
Ö
This noise is generated from the
unit when it is expands or contracts
with temperature changes.
Odor:
Ö
Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.
The unit does not start
nor change operation
mode immediately:
Ö
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.
MALFUNCTION ANALYSIS
Malfunction code
H8 Tank is full of water.
1. Pour out the water inside tank.
2. If "H8" still exits, please contact
professional person to maintain
the unit.
F1 Malfunction of ambient
temperature sensor.
Please contact professional person
to deal with it.
F2 Malfunction of evapora-
tor temperature sensor.
Please contact professional person
to deal with it.
F0 1. Refrigerant is leaking.
2. System is blocked.
1. Re-energize the unit after turning
off and pulling out the plug for
30min;
2. If there's still malfunction, please
contact after-sales service.
H3 Overload protection for
compressor.
1. If ambient temperature is too
high, power off the unit and then
energize it for operation after the
ambient temperature drops to be-
low 35°.
2. Check if the evaporator and con-
denser are blocked by some ob-
jects. If yes, take away the ob-
jects, power off the unit and then
energize it for operation.
3. If the malfunction still occur,
please contact our after-sales
service center
E8 Overload malfunction
F4 Outdoor tube
temperature
sensor is open/
short-circuited.
12. SPECIFICATIONS
MODEL
TAD-120E
TAD-126E
TAD-129E
POWER SOURCE
Single Phase
220~240 V, 50 Hz
Single Phase
220~240 V, 50 Hz
Single Phase
220~240 V, 50 Hz
COOLING CAPACITY
2.05 kW
(7,000BTU)
2.64 kW
(9,000BTU)
2.93 kW
(10,000BTU)
COOLING POWER INPUT
780 W
1,010 W
945 W
EE Class / EER*
A / 2.63
A / 2.61
A
+
/ 3.10
POWER CONSMPTION IN
THERMOSTAT-OFF MODE
109 W
102 W
39 W
POWER CONSUMPTION IN
STANDBY MODE
0.5 W
0.5 W
0.5 W
DEHUMIDIFYING
CAPACITY
1.0 L/h
1.43 L/h
1.6 L/h
OPERATING CURRENT
3.5 A
4.5 A
4.3 A
AIR FLOW (MAX.)
320 m
3
/h
330 m
3
/h
360 m
3
/h
FOR ROOMS UP TO
50 - 70 m
3
65 - 90 m
3
70 - 95 m
3
OPERATING TEMP. RANGE
16°C ~ 35°C
16°C ~ 35°C
16°C ~ 35°C
SOUND POWER LEVEL
63 dB
64 dB
65 dB
UNIT PROTECTION
IP X0
IP X0
IP X0
FUSE RATING
250V; 3,15A
250V; 3,15A
250V; 3,15A
DIMENTIONS (W×H×D)
315 × 770 ×
395 mm
315 × 770 ×
395 mm
390 × 820 ×
405 mm
WEIGHT
24.0 kg
27.5 kg
36.0 kg
COMPRESSOR
ROTARY
ROTARY
ROTARY
REFRIGERANT
R-410A / 410g
R-32 / 350g
R-32 / 550g
GWP 2088
675
675
*Conform to EN-14511:2013
NOTE: Cooling air capacity will vary according to temperature and
humidity of the room.
$0/5"*/4 '-603*/"5&% (3&&/)064& ("4&4 $07&3&% #:
5)&,:05013050$0-
)&3.&5*$"--:4&"-&%4:45&.
13. VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling effi-
ciency will be enhanced by using the following venting kit accesso-
ries.
USING EXHAUST DUCT SET (Fig. H)
1. Prepare the below accessory.
H1 Exhaust duct hose adapter nozzle. (Fix to unit)
H2 Exhaust duct hose
H3 Exhaust nozzle (upper) + Exhaust nozzle (lower)
2. To fix the Exhaust nozzle (upper) and the Exhaust nozzle (low-
er) together, press the clasp forcibly into the groove. (Fig. H4)
3. Insert one end of exhaust duct hose (flexible tube) (H2) into
exhaust duct hose adapter nozzle (H1) by turning it counter
clockwise. And install exhaust nozzle (upper + lower) (H3) into
another side of exhaust duct hose. (Fig. H5)
4. Face the side with “TOP” upwards.Insert exhaust duct hose
adapter nozzle into the groove of exhaust outlet until you hear
a sound. (Fig. H6)
5. Place the exhaust hose outdoors. (Fig. H7)
NOTE: Place the unit as close as possible to the window or
door. (H5, H6, H7)