CH - 1 4
C H A R G I N G SYSTEM
-
Alternator
I N S PECTI O N O F ALTE RNATOR
Rotor
'-
INSPECT ROTOR FOR OPEN CIRCUIT
Using a n ohmmeter. check t h o ! there is continuity bel
ween the slip rings.
S t a ndard
resista nce:
w/o
Ie
regulator
1 2V
type
3.9-4.1
0:
24V
type
1 8 .8- 1 9.2
n
wi
Ie
regulator
1 2 V
type
2 . 8 -3.0
n
24V
type
8 . 8 - 9 . 2
0:
If there is no continuity. replace the rotor.
2.
I N SPECT ROTOR F O R GRO U N D
Using an oh mmeter. check that t h e re is no continuity bel
ween the slip ring and the rotor
I f there is continui ty, replace the rOlor.
3.
INSPECT SLIP R I N G S
(t1)
C h e c k t h a t the slip r i n g s a r e not r o u g h or scored
rough
or
scored, replace the rotor.
(b) Using calipers, measure the slip ring diameter.
Standard diameter:
32.3 - 32.5
m m
1 1 . 2 7 2 - 1 .280
in.)
Minimum
d i a m e t e r :
3 2 . 1 mm { 1 .264
i n . !
If
t h e diameler is less Ihan minimum, replace the rotOr.
Stator
1.
I N S PECT STATOR FOR OPEN C I RC U I T
Using a n Ohmmeter,
check
lhat t here is c o n t i n u i t y bet
ween t h e coil leads.
If the
r
e
is no continuily, replace the stator
2.
I N S PECT STATOR FOR GRO U N D
Using a n ohmmeter, check l ilal there is no continuity bet
ween the coil leads and stator core.
I f t h ere is contin uity. replace the stator.
..,
Содержание 12H-T
Страница 1: ...TOYOTA 2 H 1 2 H T ENGINE REPAIR MANUAL Nov 1985 ...
Страница 216: ...FU SS FUEL SYSTEM Injection Pump 20 wi PS OR A C INSTALL IDLE UP ACTUATOR ...
Страница 329: ...B 1 STA N DARD B O LT TO RQ U E S P EC I F ICAT I O N S Page STAN DARD BOLT TORQUE SPECIFICATIONS 8 2 ...
Страница 332: ...SST AND S S M SST ISPECIAl SERVICE TOOLS SSM ISPECIAl SE RVICE MATERIALS C l Page C 2 C 7 ...