ST-22
STARTI N G SYSTEM
-
Electrical Diesel Injection Con trol (EDICI System
37.5'
B.
A f t e r Starting (Drive Position)
After starling the engine, t h e pump adjusting lever should
be positioned to the drive
position.
c.
Engine Stopping Action (Stop Pos ition)
When the ignition
switch i s
t u rned to
"OFF,"
the
pump
adjusting lever should move to the stop position and the
engine should SlOp.
D . Reverse
Rotation
Preve ntion
S lart the engine. and ground the oil pressure switch con
nector Then t h e pump adjusting lever should move to t he
stop position and t h e engine should st o p.
I N S PECTION OF C O M PO N E N TS
E D I C M otor
INSPECT EDIC MOTOR
C heck the continuity between t h e terminals and
body
ground.
Terminal
lever
Overinjection position
Drive
position
SlOP
position
0.1
If
continuity
is
not as
specified,
replace the
motor
Oil Pressure Switch
INSP ECT OIL P R E S S U R E SWITCH
Bod,
C heck t he continuity between the terminal and body
ground.
(el
Check that there i s continuity with t h e engine SlOp
ped.
(bl C heck that there
I S
no continuity with the
engine
run-
ning.
NOT E ·
A
f
l
e
r
t h e engine has started,
oil
pressure should
rise over
0.2
kg/cm2
12.8
psi, 20
kPa).
I f operation is not correct. replace the switch.
Содержание 12H-T
Страница 1: ...TOYOTA 2 H 1 2 H T ENGINE REPAIR MANUAL Nov 1985 ...
Страница 216: ...FU SS FUEL SYSTEM Injection Pump 20 wi PS OR A C INSTALL IDLE UP ACTUATOR ...
Страница 329: ...B 1 STA N DARD B O LT TO RQ U E S P EC I F ICAT I O N S Page STAN DARD BOLT TORQUE SPECIFICATIONS 8 2 ...
Страница 332: ...SST AND S S M SST ISPECIAl SERVICE TOOLS SSM ISPECIAl SE RVICE MATERIALS C l Page C 2 C 7 ...