Installation
32
TOX_Manual_FinePress_PFS-PFL-PFW_en
6.3.3
Installing the stroke counter (optional)
3
1
2
1
Pressure switch
2
Screw plug for counter con-
nection
3
Counter housing
1.
Disconnect the cable set from the counter housing.
2.
Screw out the screw plug on the counter connection.
3.
Install the pressure switch in the counter connection.
4.
Install the counter housing on the press head.
5.
Connect the cable set with the counter housing and pressure switch.