ü
Set the fine adjustment on the largest opening. See
justment of working stroke, Page 48
.
1.
Remove the cover from the press frame.
2.
Loosen the fastening screws of the clamping plate. Do not unscrew the
screws!
3.
Place the supplied crank onto the square and adjust the open height by
turning it.
Turning clockwise - increases the open height.
Turning anti-clockwise - reduces the open height.
4.
Remove the crank and stow it away.
5.
Tighten the fastening screws of the clamping plate. Observe the tight-
ening torques, see
Inspecting the fastening of the press head, Page
.
6.
NOTE!
Damage on the tool! The tool must be aligned!
7.
Place the cover on the press frame.