Installation
TOX_Manual_FinePress_PFS-PFL-PFW_en
33
6.3.4
Installing the force sensor (optional)
6
7
4
8
2
3
1
5
1
Screw clamp
2
Cable clamp
3
Angled plug
4
Force sensor
5
Screw fixing device
6
Clamp
7
Straight connector
8
Fixing device
1.
Screw the fixing device onto the press head.
2.
Screw the force sensor onto the ram.
3.
Fasten the cable clamp with the screw.
4.
Connect the angled plug to the force sensor.
5.
Screw the clamp in the lowest position onto the fixing device.
6.
Connect the straight connector to the evaluation unit and insert it into
the clamp.