Connect the receiver box to the cable near the stove, insert 4 x AA batteries. 
Place the 9v battery into the handset. 
 
To open the air vent press the smallest button on the handset at the same time as the button 
next to the arrow pointing upwards. To close the air vent, just press the button next to the 
arrow pointing downwards. 
 
 
 
 

TO INSTALL EXTERNAL AIR SUPPLY   

 
Put one jubilee clip over the flexi vent pipe.    Push the vent pipe onto the rear air outlet on 
the stove and tighten the jubilee clip.    Drill a 100mm hole through the wall with a core drill 
and push the vent pipe through the wall, cutting to correct length. Put the second jubilee 
clip round the vent pipe then fasten to louvre grill.    Back fill round the outside of the vent 
pipe with insulating material to prevent draught getting into the house. Then fasten the 
louvre grill onto the wall. 
 
 

TURBO BURNER 
 

There is a Turbo Burner which brings air in allowing plenty of oxygen into the rear and top 
of the stove, thus burning off gases which normally do not ignite. This gives the stove more 
efficiency and better combustion, less pollution. The turbo burner is built in and needs no 
adjustment. 
 

LIGHTING THE STOVE

 

 
When ready to light the stove for the first time, make sure that everything is removed from 
the ashpan, and then open the lever under the door to the left, this is operated by hand with 
a glove or by foot. Then slide the air inlet on the right hand side of the stove towards the 
front to let air in under the grate, this is meant for cold start or to be used when refueling.     
First burn some newspaper in the stove, with the door closed, to warm the flue, as there 
may be down draught initially. The temperature in the flue has to be increased to change the 
down draught to up draught. If down draught persists, try burning a blow torch in the stove, 
facing the flue for a minute or two. If there is a soot door fitted, try warming the flue 
through the soot door. If this does not work, call in your installer. If the stove has not been 
lit for a while, the chimney should be checked for blockages before lighting. 
When ready to light the stove, put a small piece of fire lighter, about 25mm square is big 
enough, and then add small sticks, taking care not to smother the flames. When the sticks 
are well alight add small logs, gradually increasing the size. Once the fire is well 
Established and hot the bottom air slide can be closed. A stove handle cover is included 

Содержание Caedmon ECO Smoke Control

Страница 1: ... If there is a possibility of disturbing asbestos during the installation it is necessary to take the appropriate steps to protect the installer Fire cement is caustic and protective gloves should be worn The chimney must be swept and examined for soundness and suitability before the stove is installed Remedial action should be taken if required seeking expert advice if necessary Where the chimney...

Страница 2: ... the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ir...

Страница 3: ...mm at the back and 400 mm at the sides must be maintained from combustible materials It is a requirement that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations The Caedmon Eco Design has been tested for hearth temperatures and the maximum temperature was 56 degrees so is also suitable for a 12mm hearth INSTALLATION A minimum flue draught...

Страница 4: ...flue pipe to an existing chimney a register plate is required preferably made of metal Acollar is welded to the underside of the register plate so that the flue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of s...

Страница 5: ...ess pollution The turbo burner is built in and needs no adjustment LIGHTING THE STOVE When ready to light the stove for the first time make sure that everything is removed from the ashpan and then open the lever under the door to the left this is operated by hand with a glove or by foot Then slide the air inlet on the right hand side of the stove towards the front to let air in under the grate thi...

Страница 6: ...operating tool stove handle cover and a pair of gloves are provided for operation of the hot stove The appliance is designed to operate efficiently with the fire door closed The door should be kept closed at all times except when refueling or removing ashes STOVE HANDLE COVER There is a black stove handle included with your stove this is to be used when opening and closing the stove door Place the...

Страница 7: ...tee Wood needs to be dry and seasoned maximum 20 moisture content Do not burn any liquid fuel Do not burn wood pellets do not burn wood chips Do not burn any rubbish on the stove CLEANING THE STOVE AND FLUE It is important to remove the ashes regularly if the ash builds up through the grate the grate could overheat and distort Open the fire door with the stove glove provided and using the tool gen...

Страница 8: ...ates and the chimney are swept prior to lighting up after a prolonged shutdown period TROUBLE SHOOTING 1 The stove is not burning well The stove may need more fuel loading load more fuel see lighting the stove The wood may be un seasoned or damp avoid using unsuitable wood The chimney may need sweeping or there may be a build up of debris above the baffle see Cleaning the Stove and Flue There may ...

Страница 9: ...MAKE SURE THERE IS NOTHING COMBUSTIBLE NEAR THE STOVE MOVE PEOPLE AWAY FROM THE ROOM CLOSE THE ROOM DOOR PHONE THE FIRE BRIGADE COMMISSIONING AND HAND OVER INSTRUCTIONS Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire chec...

Страница 10: ...n EU 2015 1187 Energy Labelling of Local Space Heaters Supplier s Name or Trademark Town Country Fires Suppliers Model Identifier Caedmon Eco Design SC Energy Efficiency Class of Model A Nominal Heat Output to Room kW 7 0 Nominal Heat Output to Water kW n a Net Efficiency 76 0 Energy Efficiency Index 100 ...

Страница 11: ...ur Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Paint Claims under this guar...

Страница 12: ...bricks out see picture below The second side brick can now easily be removed Repeat to remove the other side brick Remove top baffle Loosen dome nut on the tertiary air control at the left hand side of the stove body remove the top rear brick Then the remaining rear bricks and air tube can be removed through the front of the stove Please note the correct position for the first baffle is with the n...

Страница 13: ...elope to Town and Country Fires Ltd Unit 1 Enterprise Way Thornton Road Ind Estate Pickering North Yorkshire YO18 7NA Model Serial No CAESCED Date of Purchase Title Surname Address Date of Installation Installers Name HETAS Reg No Address Tel No Supplier Details Name Address Tel No Thank you for your co operation if you do not wish to be contacted by Town and Country Fires in the future please tic...

Отзывы: