background image

CAEDMON ECO DEISGN SMOKE CONTROL ISSUE No. 02    10/10/2017 

 

 

 

UNPACK THE STOVE

 

 

Carefully cut the straps and lift the box up over the top of the stove. Remove the packing 
from round the outside of the stove, 

leaving the plastic cover on if building work is still 

in progress, it is important to protect the paint finish from any damage, water, dust or 
fire

 

cement

. Using a 17mm spanner, remove the two bolts attaching the stove to the pallet, 

and then replace the bolts into the stove legs, these are used as levelling bolts if required.     
Open the stove door and remove the packaging from inside the stove, there is some behind 
the baffle, and the heavy one inside the stove contains the spigot for the flue outlet.   
Remove the bag inside the ashpan, this contains the operating tool, instructions, and a pair 
of stove gloves. 
 

CLEARANCES 
 

The Caedmon Eco Design needs to be sited next to and on a non-combustible surface. A 
minimum clearance of 150mm at the sides 300mm above and 50mm from the back of the 
stove body will allow air circulation and not impede the performance of the stove.     
If it is necessary to site the stove near a combustible surface a minimum of 200mm at the 
back and 400 mm at the sides must be maintained from combustible materials. 
 
It is a requirement that this appliance is installed on a solid, level, non-combustible hearth 
conforming to current Building Regulations. The Caedmon Eco Design has been tested for 
hearth temperatures and the maximum temperature was 56 degrees so is also suitable for a 
12mm hearth. 
 

INSTALLATION 

 

A minimum flue draught of 24 Pa is required for nominal heat output. The Appliance must 
be installed on a floor with an adequate load-bearing capacity.    If an existing construction 
doesn’t meet the prerequisite, suitable measures (e.g. load distributing plate) shall be taken 
to achieve it.    As referred to in document J in the Building Regulations, the Caedmon Eco 
Design requires a minimum of 1100 sq mm of fixed ventilation (this equals ventilation of 
approximately 33mm x 33mm). 

It is important that any inlet grilles are so positioned that they are not liable to blockage. It 
is essential that the stove has adequate air supply for combustion and ventilation. 
Apertures provided for this purpose shall not be restricted. 

 

Please note where either the external air kit or remote control kit are fitted an air vent 
is still required in the same room as the stove to the above specification. 

 

Fit the collar on the top of the stove. A flat-bladed screw driver and 8mm spanner will be 

Содержание Caedmon ECO Smoke Control

Страница 1: ... If there is a possibility of disturbing asbestos during the installation it is necessary to take the appropriate steps to protect the installer Fire cement is caustic and protective gloves should be worn The chimney must be swept and examined for soundness and suitability before the stove is installed Remedial action should be taken if required seeking expert advice if necessary Where the chimney...

Страница 2: ... the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ir...

Страница 3: ...mm at the back and 400 mm at the sides must be maintained from combustible materials It is a requirement that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations The Caedmon Eco Design has been tested for hearth temperatures and the maximum temperature was 56 degrees so is also suitable for a 12mm hearth INSTALLATION A minimum flue draught...

Страница 4: ...flue pipe to an existing chimney a register plate is required preferably made of metal Acollar is welded to the underside of the register plate so that the flue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of s...

Страница 5: ...ess pollution The turbo burner is built in and needs no adjustment LIGHTING THE STOVE When ready to light the stove for the first time make sure that everything is removed from the ashpan and then open the lever under the door to the left this is operated by hand with a glove or by foot Then slide the air inlet on the right hand side of the stove towards the front to let air in under the grate thi...

Страница 6: ...operating tool stove handle cover and a pair of gloves are provided for operation of the hot stove The appliance is designed to operate efficiently with the fire door closed The door should be kept closed at all times except when refueling or removing ashes STOVE HANDLE COVER There is a black stove handle included with your stove this is to be used when opening and closing the stove door Place the...

Страница 7: ...tee Wood needs to be dry and seasoned maximum 20 moisture content Do not burn any liquid fuel Do not burn wood pellets do not burn wood chips Do not burn any rubbish on the stove CLEANING THE STOVE AND FLUE It is important to remove the ashes regularly if the ash builds up through the grate the grate could overheat and distort Open the fire door with the stove glove provided and using the tool gen...

Страница 8: ...ates and the chimney are swept prior to lighting up after a prolonged shutdown period TROUBLE SHOOTING 1 The stove is not burning well The stove may need more fuel loading load more fuel see lighting the stove The wood may be un seasoned or damp avoid using unsuitable wood The chimney may need sweeping or there may be a build up of debris above the baffle see Cleaning the Stove and Flue There may ...

Страница 9: ...MAKE SURE THERE IS NOTHING COMBUSTIBLE NEAR THE STOVE MOVE PEOPLE AWAY FROM THE ROOM CLOSE THE ROOM DOOR PHONE THE FIRE BRIGADE COMMISSIONING AND HAND OVER INSTRUCTIONS Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire chec...

Страница 10: ...n EU 2015 1187 Energy Labelling of Local Space Heaters Supplier s Name or Trademark Town Country Fires Suppliers Model Identifier Caedmon Eco Design SC Energy Efficiency Class of Model A Nominal Heat Output to Room kW 7 0 Nominal Heat Output to Water kW n a Net Efficiency 76 0 Energy Efficiency Index 100 ...

Страница 11: ...ur Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Paint Claims under this guar...

Страница 12: ...bricks out see picture below The second side brick can now easily be removed Repeat to remove the other side brick Remove top baffle Loosen dome nut on the tertiary air control at the left hand side of the stove body remove the top rear brick Then the remaining rear bricks and air tube can be removed through the front of the stove Please note the correct position for the first baffle is with the n...

Страница 13: ...elope to Town and Country Fires Ltd Unit 1 Enterprise Way Thornton Road Ind Estate Pickering North Yorkshire YO18 7NA Model Serial No CAESCED Date of Purchase Title Surname Address Date of Installation Installers Name HETAS Reg No Address Tel No Supplier Details Name Address Tel No Thank you for your co operation if you do not wish to be contacted by Town and Country Fires in the future please tic...

Отзывы: