background image

CAEDMON ECO DEISGN SMOKE CONTROL ISSUE No. 02    10/10/2017 

 

 

required. 
The Caedmon Eco Design requires a Class 1 chimney of its own, a shared chimney will not 
be suitable.    The chimney must be sound, free from leaks and swept before installation. If 
the chimney requires lining, a lining must be used which is suitable for wood and solid fuel, 
with a minimum of 150mm internal diameter. A meter of flue pipe should be used from the 
stove before the chimney lining, and the lining must be installed to manufacturers’ 
instructions.    Alternatively, if there is no chimney, then an insulated stainless steel flue 
may be used, to BS EN 15287-1:2007 + A1:2010 with a minimum of 150mm internal 
diameter, and must be installed to manufacturers’ instructions and to relevant Building 
Regulations.     
The length of the chimney or flue must be at least 4.5 meters from the top of the stove, and 
must finish in a down draught free area.    A stove must not be installed into a room where 
there is an extractor fan, or fumes could be pulled down the chimney. 
 
It is essential to provide a facility for sweeping the chimney, and this may be done by 
installing a soot door in the brickwork, or providing an access plate in the register plate or 
flue pipe. The flue is fitted from the top of the stove and the baffle can be removed to sweep 
up through the stove.   
To connect the flue pipe to an existing chimney, a register plate is required, preferably 
made of metal.    A collar is welded to the underside of the register plate so that the flue pipe 
can be placed into the spigot on top of the stove and round the outside of the collar on the 
register plate, so forming a ‘funnel’ effect. In this way, any moisture running down the 
chimney will be directed back into the stove instead of seeping out onto the top of the stove.   
 
Connect the stove to the chimney using vitreous enameled flue pipe, from the top of the 
stove. Make sure that all joints and connections are well sealed. 
 

TO INSTALL EXTERNAL AIR SUPPLY WITH REMOTE CONTROL 

 

WARNING – DO NOT FIT ANY OF THE BATTERIES UNTIL INSTALLATION IS 
COMPLETE 

 

Put one of the jubilee clips provided over the flexi vent pipe. Push the vent pipe onto the 
rear air outlet on the stove and tighten the jubilee clip. Drill a 100mm hole through the wall 
with a core drill and push the vent pipe through the wall. 

 

Take the cover off the stainless steel air intake box by undoing the two rear screws at either 
side. Feed the 1.5m braided lead through the wall into the stove position. Connect the flexi 
air intake pipe to the back of the stove using the clip provided. Feed the flexi pipe through 
the wall, gently pushing the stove into place and connect the outside air vent onto the metal 
tube connected to the back plate. Wrap the 13mm ceramic rope provided round the pipe and 
place silicone sealer round the outside of the back plate. Screw the back plate to the wall 
and replace the cover. 
 

Содержание Caedmon ECO Smoke Control

Страница 1: ... If there is a possibility of disturbing asbestos during the installation it is necessary to take the appropriate steps to protect the installer Fire cement is caustic and protective gloves should be worn The chimney must be swept and examined for soundness and suitability before the stove is installed Remedial action should be taken if required seeking expert advice if necessary Where the chimney...

Страница 2: ... the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ir...

Страница 3: ...mm at the back and 400 mm at the sides must be maintained from combustible materials It is a requirement that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations The Caedmon Eco Design has been tested for hearth temperatures and the maximum temperature was 56 degrees so is also suitable for a 12mm hearth INSTALLATION A minimum flue draught...

Страница 4: ...flue pipe to an existing chimney a register plate is required preferably made of metal Acollar is welded to the underside of the register plate so that the flue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of s...

Страница 5: ...ess pollution The turbo burner is built in and needs no adjustment LIGHTING THE STOVE When ready to light the stove for the first time make sure that everything is removed from the ashpan and then open the lever under the door to the left this is operated by hand with a glove or by foot Then slide the air inlet on the right hand side of the stove towards the front to let air in under the grate thi...

Страница 6: ...operating tool stove handle cover and a pair of gloves are provided for operation of the hot stove The appliance is designed to operate efficiently with the fire door closed The door should be kept closed at all times except when refueling or removing ashes STOVE HANDLE COVER There is a black stove handle included with your stove this is to be used when opening and closing the stove door Place the...

Страница 7: ...tee Wood needs to be dry and seasoned maximum 20 moisture content Do not burn any liquid fuel Do not burn wood pellets do not burn wood chips Do not burn any rubbish on the stove CLEANING THE STOVE AND FLUE It is important to remove the ashes regularly if the ash builds up through the grate the grate could overheat and distort Open the fire door with the stove glove provided and using the tool gen...

Страница 8: ...ates and the chimney are swept prior to lighting up after a prolonged shutdown period TROUBLE SHOOTING 1 The stove is not burning well The stove may need more fuel loading load more fuel see lighting the stove The wood may be un seasoned or damp avoid using unsuitable wood The chimney may need sweeping or there may be a build up of debris above the baffle see Cleaning the Stove and Flue There may ...

Страница 9: ...MAKE SURE THERE IS NOTHING COMBUSTIBLE NEAR THE STOVE MOVE PEOPLE AWAY FROM THE ROOM CLOSE THE ROOM DOOR PHONE THE FIRE BRIGADE COMMISSIONING AND HAND OVER INSTRUCTIONS Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire chec...

Страница 10: ...n EU 2015 1187 Energy Labelling of Local Space Heaters Supplier s Name or Trademark Town Country Fires Suppliers Model Identifier Caedmon Eco Design SC Energy Efficiency Class of Model A Nominal Heat Output to Room kW 7 0 Nominal Heat Output to Water kW n a Net Efficiency 76 0 Energy Efficiency Index 100 ...

Страница 11: ...ur Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Paint Claims under this guar...

Страница 12: ...bricks out see picture below The second side brick can now easily be removed Repeat to remove the other side brick Remove top baffle Loosen dome nut on the tertiary air control at the left hand side of the stove body remove the top rear brick Then the remaining rear bricks and air tube can be removed through the front of the stove Please note the correct position for the first baffle is with the n...

Страница 13: ...elope to Town and Country Fires Ltd Unit 1 Enterprise Way Thornton Road Ind Estate Pickering North Yorkshire YO18 7NA Model Serial No CAESCED Date of Purchase Title Surname Address Date of Installation Installers Name HETAS Reg No Address Tel No Supplier Details Name Address Tel No Thank you for your co operation if you do not wish to be contacted by Town and Country Fires in the future please tic...

Отзывы: