UNIT MAY BE RECESSED UP TO 4 1/2” WITH
NONCOMBUSTIBLE MASONRY TYPE MATERIAL
Minimum Clearances:
Side standoffs .................................. 0 in.
(0 mm)
Back standoffs ................................. 0 in.
(0 mm)
Top standoffs .................................... 0 in.
(0 mm)
Bottom of appliance ......................... 0 in.
(0 mm)
Adjacent side wall ............................ 4 in.
(102 mm)
Ceiling to appliance ........................ 24 in.
(610 mm)
*Mantel to appliance See Figure #2
**Maximum Mantel extension See Figure #2
Mantel support ................................. 4 in.
(102 mm)
Vent pipe including Elbows ...... 1 3/4" in.
(45 mm)
* MANTEL CLEARANCE
A
9”
B
6”
C
3”
** MANTEL DEPTH
D
12”
E
6 3/4”
F
1 1/2”
MANTEL CLEARANCE
CHART
Fireplace Dimensions
Minimum Clearances to Combustible Material
22 1/8"
7 5/8"
45 1/16"
23 3/8"
57 15/16"
48 7/16"
40 7/16"
5 15/16"
24 7/8"
29 3/4"
22 1/8"
Figure 1: TC38WS Dimensions.
A
B
C
D
E
F
S
te
el F
rame
Non-combustible board
Combustible board
Stand off
= Non-combustible zone. Do not install
any combustible material, electrical wiring
or gas plumbing in this area.
Top of lintel bar
Figure 2: TCWS38 Mantel clearances.
21 5/8"
24"
4“
CEILING
ADJACENT WALL
OR MANTEL SUPPORT
6”
COMBUSTIBLE FL
OOR
*
**
Figure 3: TCWS38 Mantel clearances.
5056.42523D2
5
TCWS38Dver2_140817-44