Figure 68: Pilot assembly.
CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for
unit to cool before servicing appliance. It is recommended that the fireplace
and its venting should be inspected at least once a year by a qualified service
person.
Glass Panel:
Warning: Do not operate fireplace with glass panel removed, cracked or bro-
ken. Replacement of the glass panel should be done by a licensed or qualified
service person.
Do not strike or otherwise impact the glass in anyway that may cause it to
break. If the glass becomes cracked or broken it must be replaced before using
the fireplace. Replacement glass can be obtained from your nearest Town &
Country Fireplaces dealer. The size required is 38" x 14" x 5mm. Use ceramic
glass only. Do not substitute with any other type.
To remove broken glass, remove window frame as noted in "Window Frame
Removal" section.
Unclip the Glass Retainer Clips located at the top and sides of the Window
Frame. Pull the top edge of the glass out of the frame first, then lift it up and out
of the bottom edge.
Install the new piece of glass with the gasket into the frame so that the thicker
bead of gasket faces the fireplace.
Re-install glass retaining clips.
Annual Inspection:
a) Remove glass panel and burner assemblies. Inspect for soot buildup. If excessive buildup of soot is present, have a
qualified service person inspect and adjust unit for proper combustion. Clean burner assembly with a brush or vac-
uum cleaner, paying close attention to burner ports.
b) Check the pilot system (Figure 68) for proper flame size and operation. Clean pilot free of soot, dust or any other
deposits.
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled
for cleaning, it must be properly assembled and re-sealed. Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable
vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.
b) Exterior finish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fireplace.
Do not clean glass when hot.
PILOT FLAME
FLAME SENSOR
ELECTRODE
PILOT
Maintenance
5056.42523D2