Hearth Extension
Caution: While a hearth extension is not required and combustible fl ooring
materials may be brought directly up to the fi replace, many materials (such as
wood fl ooring) may not tolerate the radiant heat from this fi replace, resulting in
discoloration, shrinking and cracking. For this reason, we suggest a non-com-
bustible hearth that is no more than 1” above the bottom of the fi replace. If
thicker, fi replace must be raised accordingly.
Caution: Hearth extensions thicker than 1” will interfere with the safety screen
and window frame when opening.
Bottom of fireplace
Maximum
heigth of 1”
above bottom
of fireplace
Lintel
Hearth
Extention
Figure 24: TCWS38D2 Hearth extension.