Roof Vent Terminal:
1. Place the roof fl ashing over top of the vent pipe and seal it to the roof using the meth-
ods and materials appropriate for the type of roof on the building. Shingle roof example
shown. (Fig. #29)
2. Place the storm collar down over the vent pipe until it is level. Tighten storm collar for
a snug fi t. Apply a thick horizontal ring of mastic around the pipe at top of the storm
collar. (Fig. #29)
3. Lower the roof vent terminal cap over the vent pipe and secure in place with screws
provided. (Fig. #29) Seal screw heads and joint with caulking to prevent any moisture
entering the venting system.
Fig. #29
VERTICAL TERMINATION CAP
(TCVT.9365)
FLASHING
STORM COLLAR
(TC42.90665)
MASTIC
NOTE: ADJUSTABLE FOR VARIOUS ROOF
PITCHES, FROM FLAT ROOF TO 12/12
PITCH ROOF.
VENT PIPE
19
TCWS.54CE2 200810-40