The gas control system is located on the right hand side of the fi rebox behind an access
panel and the decorative fi rebox panel (if installed). The fi replace is operated via a wall
switch and a hand held remote control unit.
The wall control is connected to the fi replace by a 25 ft. communication cable supplied with the
fi replace. The communication cable can be extended with an optional 25 ft. extension kit.
Installation
1. Place the fi replace in the desired location.
2. Remove the window from the fi replace.
3. Remove access panel from right hand side of the fi rebox (Fig. #16)
4. Lift the control box heat shield from the bottom opening to clear the location tabs and
pull inwards. Lower the heat shield to clear the top tab. Lift the heat shield and locate
on the screw above the opening. (Fig. #17 & 18)
NOTE: The fl ex lines may have to be pushed down to allow the shield to be lowered
enough to clear the top tab.
5.
Connect a 110 V. AC electrical supply to the outlet installed inside the control box
(Fig.
#19)
6. Connect the gas supply to the valve (Fig. #19)
7.
Plug the A/C adaptor into the outlet (Fig. #19)
8. Attach the electrical box for the supplied wall control to the framing in the desired
location (up to 50 ft. away). (25 ft. is supplied with fi replace. An additional 25 ft. can
be achieved by using the optional kit (Part # 5005.064) available from your
dealer).
WARNING: The control box heat shield and access panel must be replaced.
Failure to do so will overheat and cause premature failure of the control.
OUTLET
Fig. #19
Fig. #18
Fig. #17
GAS CONNECTION
A/C ADAPTER
Fig. #16
HEAT SHIELD
ACCESS PANEL
13
TCWS.54CE2 200810-40
Maestro Control
– Plumbing and Electrical