The top standoffs are shipped loose inside
the fi replace and must be installed on top of
the fi replace as shown in Fig #10. Do this
once the fi replace is on site and in position.
In planning the installation for the fi replace, it is necessary to determine where the unit is to
be installed, location of vent system and where gas supply piping may be plumbed. Various
installations are possible, such as, into an existing wall, a corner, a built-in wall or a wall
projection (Fig #11). Due to high temperatures, do not locate this fi replace in areas of high
traffic or near furniture or draperies.
The minimum clearances from the fi replace to combustible surfaces must be adhered
to and are shown in Fig #6 and Fig #7.
Fig. #10
TOP STANDOFFS
EXAMPLES OF COMMON LOCATIONS
SEE FIG #15 FOR DIMENSIONS
Fig. #11
9
TC36.COD 102513-40
Locating The Fireplace
Top Standoffs