WALL THIMBLE AND VENT MUST NOT PROTRUDE BEYOND SIDING
Fig. #35
Wall thimble:
Where a vent pipe passes through a combustible wall, a wall thimble/shield must be used
to retain insulation and maintain proper clearances. The wall thimble may be cut to length
for various wall thicknesses up to 12" thick.
Measure the wall thickness including the siding. Trim the shield to match the wall thickness.
Position the wall thimble from inside through the 14-1/2" opening. Properly adjusted, the
thimble should be flush with the outer wall surface.
TRIM TO LENGTH
Fig. #36
Vent System Components
Town & Country
12" Pipe Length .................................................... TCVT.811X12
18" Pipe Length .................................................... TCVT.811X18
24" Pipe Length .................................................... TCVT.811X24
48" Pipe Length .................................................... TCVT.811X48
12" Adjustable Pipe Length ................................... TCVT.811X12ADJ
45° Elbow ............................................................. TCVT.811XLB45
90° Elbow ............................................................. TCVT.811XLB90
Wall/Offset Support .............................................. TCVT.811XOS
Wall Termination Kit .............................................. TCVT.WTA
Roof Termination Kit ............................................. TCVT.RTA
Wall Shield/Ceiling Firestop .................................. TCVT.THIMA
Roof Flashing, Adjustable ..................................... TCVT.811FLADJ
Roof Flashing, Flat ............................................... TCVT.811FLFLT
Roof Flashing, Steep ............................................ TCVT.811FLSTP
or any flashing that fits 11" pipe
Fig. #37
21
TC36.CE3 250313-48