The gas control system is located on the right hand side of the firebox behind an access
panel and the decorative firebox panel (if installed). The fireplace is operated via a wall
control and a hand held remote control unit.
The wall control is connected to the fireplace by a 25 ft. communication cable supplied with the
fireplace. The communication cable can be extended with an optional 25 ft. extension kit.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Fig #25)
4. Connect a 110 V. AC electrical supply to the outlet installed inside the control box
(Fig #26). The fireplace operates on a low voltage supplied by an AC adaptor rated at
110 volts, 60Hz, 0.25A. The optional power vent kit is rated at 115 volts, 60Hz, 1.8A.
The electrical wires can be accessed from both inside and
outside the control box by removing one of the two small
access panels (Fig #27)
The wires from inside the outlet box are connected to
the 110 V.AC supply (Fig.#28)
5. Connect the gas supply to the valve (Fig #26)
6. Plug the A/C adaptor into the outlet (Fig #26)
7. Attach the electrical box for the supplied wall control to the framing in the desired
location (up to 50 ft. away). (25 ft is supplied with fireplace. An additional 25 ft can
be achieved by using the optional kit (Part # 5005.064) available from your
distributor).
OUTLET
ADAPTOR
Fig. #28
Fig. #27
Fig. #26
GAS CONNECTION
ACCESS PANEL
Fig. #25
16
TC36.CE3 250313-48
Maestro Control
Plumbing and Electrical
Содержание TC36.CARE3
Страница 46: ...Notes 46 TC36 CE3 250313 48 ...