Push buttons, key switches or external radio receivers with potential-free make contacts can be used as pedestrian
button.
Pedestrian button
(terminals 30/34)
Buttons/switches
OPEN/STOP/CLOSE successive impulses:
An impulse through the pedestrian button-while the gate is in motion-
causes gate stopping. If the gate is within the pedestrian area, then an impulse through the pedestrian button causes
inversion of the direction.
If the gate is in complete open position an impulse through the pedestrian button causes a movement in CLOSE direc-
tion and the gate stopps at pedestrian OPEN position.
OPEN/CLOSE/OPEN successive impulses:
If the gate is within the pedestrian area, then an impulse through the pedestrian button causes inversion of the direction.
If the gate is in complete open position an impulse through the pedestrian button causes a movement in CLOSE direction
and the gate stopps at pedestrian OPEN position.
•
In this operation mode it is not possible to stop the motor with the pedestrian button – it always
moves until reaching an end position. (Opened or closed position).
• for the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell! !
OPEN:
Only opening commands are accepted by the impulse switch – closing the gate with the impulse switch is not
possible.
DEADMAN:
The motor opens as long as the impulse switch is pressed (hold) – closing the gate with the impulse switch
is not possible. As soon as the switch is released, the motor stops.
As soon as the deadman function is activated, the radio receiver is without function (due to safety reasons).
The DEADMAN function can not be chosen actively but is set automatically as soon as the impulse
button is set to DEADMAN mode.
STOP-switch
(terminals 30/31)
Buttons / switches
• when pressing the stop switch the gate stops in any desired position.
As stop switch a break contact has to be used.
If no stop switch is connected, terminals 30/31 have to be wire-bridged.
31
30
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!