![tousek ST 12/5 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/tousek/st-12-5/st-12-5_connection-and-installation-manual_1140518022.webp)
- 22 -
tousek
/ EN_ST-12-5_05 / 25. 03. 2020
6. Putting into operation
Swing gate control unit ST 12/5
Important: preparation works
• Connect control panels, safety devices to the motor under the safety regulations in .
Attention: if no stop switch is connected then the terminals 30/31 have to be bridged.
•
The mechanical limits have to be placed so that contact edges are not triggered, as this would lead to an
error message
• Unlock emergency release of operator and set gate to half-opened position. Then lock the operator again
• Then turn on the operator (correct connection necessary).
•
Important:
Putting into operation in Impulse mode (standard setting) and not in dead man mode.
• During initial operation the choice of language is made first, then in the “Basic settings” the adjustment of most impor
-
tant operator settings and after the system test, the automatic detection of limit positions of gate is made..
LANGUAGE SELECTION
•
Can be selected during initial operation (hence after reset to factory settings).
•
Can be also chosen by pressing the ESC button
( )
for 5s, from any position in menu.
BASIC SETTINGS
•
For setting the most important adjustments for initial operation of motor.
•
Can be selected during initial operation (hence when restoring the factory setting).
•
All safety devices are activated when leaving factory
(siehe menu page 7).
•
The next programming adjustments are made in the main settings menu
(see page 6–7).
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
impulse button
3
3
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
OPEN-STOP-CLOSE
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
OPEN
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
OPEN-CLOSE-OPEN
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
DEADMAN
change ? YES
confirm
confirm
confirm
3
4
3
OPEN
STOP
CLOSE
OPEN
CLOSE
OPEN
OPEN
Deadman
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Sprache-language
Deutsch
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Tousek Vx.x
ST12-5
2
1
2
3
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
basic settings
scroll
confirm
confirmation
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Sprache-language
English