Important: notes for photocells
•
The control unit has a power supply connection for 12V DC photocells (LS):
Power supply LS-transmitter: terminals 41(-) / 42(+), Versorgung LS-receiver: terminals 43(-) / 44(+)
Hinweis: Kl. 41/42 werden in der „Tor geschlossen“- Stellung in den Stromsparmodus (d.h. spannungsfrei)
geschalten.
• At supplied and positioned photocells the contact has to be closed (make contact).
Connection of outer photocell contact: terminals 45/48, inner photocell contact terminals 45/46
• When using two pairs of photocells please do not
install both photocell transmitters/receivers on the
same side (to eleminate interference between both) !
• Self-monitoring of photocells:
The control unit has a monitoring function for the connected photocells. A test will be
triggered by each ipumlse and will be checked if the receiver of the photocell responds to the signal from the photocell
transmitter. If there is no communication between the photocell receiver and transmitter the control unit responds with an error.
The deactivation of the self-test function is only permitted if the safety installations correspond to the
category 3 !
• The exact function of the photocells depends on the programming of the control unit.
Photocell functions
see menu point SAFETY/inner (outer) photocell function, resp. photocell with pause time
(page 13).
•
Detailed information you will find in the corresponding photocell manual
.
Standard:
transmitter 1
receiver 1
receiver 2
transmitter 2
INNER AND OUTER PHOTOCELL
Safety
inner photocell
outer photocell
INSIDE
• E
nergy saving mode
:
photocell transmitter is turned
off when gate is closed
• With
additional inner photocells
the back area of
the gate can be monitored. (All inner photocells are
then set in series at control terminals 45/46 (terminals
for inner photocells))..
• The exact function of the photocells depends on the
programming of the control unit:
Photocell functions
see page 13.
inner photocell for monitoring of
gate back rear (left)
inner photocell for monitoring of
gate back rea (right)
G
Inner photocell
(contact: terminals 45/46)
Safety
active:
to be selected, if inner photocell should be triggered.
not active:
to be selected, if inner photocell should not be triggered.
Safety
Connections and adjustments
G
Outer photocell
(contact: terminals 45/48)
Safety
active:
to be selected, if outer photocell should be triggered.
not active:
to be selected, if outer photocell should not be triggered.