![tousek ST 12/5 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/tousek/st-12-5/st-12-5_connection-and-installation-manual_1140518007.webp)
tousek
/ EN_ST-12-5_05 / 25. 03. 2020
- 7 -
Main layer
Sub layer
Adjustments
buttons/switches
see page 8
G
impulse button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEAD MAN
*) if impulse button is
set to DEADMAN, then
the pedestrian and
close button are also
set automatically to
DEADMAN mode.
(not selectable under
„pedest.- button“)
pedestrian button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEAD MAN
*)
safety
see page 10
G
inner
photocell
active
not active
G
outer photocell
active
not active
G
main safety edge 1
active
not active
G
main safety edge 2
active
not active
photocell function inside
during closing reverse
stop - after release open
during opening stop - then open
photocell function outside
during closing reverse
stop - after release open
PHC-pause time
no influence of photocell
abort pause time
re-start of pause time
immediate close after opening
PHC-self test
active
not active
left leaf
see page 15
motor left
motor ON
motor OFF
G
delay left leaf
opening delay
closing delay
G
delay time left
0...25s
= 2s
ARS response time
0,15...0,95s
= 0,70s
max. force
30...100%
= 70%
soft stop time
0...25s
= 5s
right leaf
see page 15
motor right
motor ON
motor OFF
G
delay right leaf
opening delay
closing delay
G
delay time right
0...25s
= 2s
ARS response time
0,15...0,95s
= 0,70s
max. force
30...100%
= 70%
soft stop time
0...25s
= 5s
operating mode
see page 16
impulse logic
stop, start of pause time
impulse suppression when opening
pause time extension
G
operating mode
impulse mode
automatic 1...255s
partial opening
25...100%
= 100%
automatic mode
complete/partial opening
only complete opening
only partial opening
pause time logic
no influence
permanent open in automatic mode
closing edges
left/right
inside/outside
lights/lamps
see page 18
prewarning OPEN
OFF, 1...30s
= OFF
prewarning CLOSE
OFF, 1...30s
= OFF
courtyard lamp
1
OFF, 5...950s
= OFF
control lamp
1
illuminates during open and close
blinks slowly/illuminates/blinks
illuminates in open position
peripherals
see page 18
electrick lock
OFF, 1...10s
= OFF
additional module
courtyard lamp/control lamp
status display 1
status display 2
diagnosis
see page 20
status display
status display
delete position
NO
YES
factory setting
NO
YES
software version
shows software version
serial number
shows serial number
protocol
shows protocole inputs
1)
the menu items courtyard lamp and control lamp will only appear on display, if under
additional module
courtyard/control lamp is selected.
Swing gate control ST12/5
+
–
Menu structure
Adjustments - overview
ESC
ENTER
Note: Some changes in the functioning or operation logic are accepted only when the gate is closed and the „Ready“ appears on t
he display
.