inSTallaTion CheCk
Turn the water on for about a minute� Place a thermometer in the water
stream to confirm that the water temperature is at 104ºF (40ºC).
If the temperature is confirmed, rotate the temperature knob, without
pressing the button, counter-clockwise until it comes to the first stop.
Confirm that the temperature is about 108ºF (42ºC).
If the temperature is confirmed, press the knob button and rotate fully
counter-clockwise until it comes to a full stop. Confirm that the temperature
does noT exceed 120ºf (49ºC)�
Once confirmed, turn the knob back to 104ºF (40ºC) and confirm that
the temperature matches the knob setting�
NOTE: If any of the above temperature settings is not confirmed, repeat
the calibration procedure steps in “CalIBraTIng The valve” section�
■
■
■
■
■