English
Faceplate
Valve
Valve
Flat
Valve
NOTE: Appearance of componenents depends
on model: TS794, TS930, or TS960 (shown)
TriM inSTallaTion
remove the protective cover from
the valve�
Place the faceplate against the
finish wall and secure with escutcheons
■
■
set the voluMe control valve
to the off position by rotating valve
so that the flat point is at the 12 O’clock
position�
for TsTd model: you will
hear a click sound
for TsTa model: you will
come to a stop�
■
Install the voluMe control
knob onto the volume control valve
with the marker at the 12 o’clock
position� Then rotate the knob fully
to the right� secure the knob with
set screw�
Carefully slide the TeMPeraTure
control knob onto the temperature
control valve with the locking button
at the 12 o’clock position� secure
the knob with set screw�
■
■