9
9
Maintenance
5
Pull out the lamp.
Loosen the lamp locking screws, pull up the
handle, and press the tab to remove the lamp.
6
Mount the new lamp.
Align the orientation, press down the new lamp
until the bottom is reached. Then lock it in
place using the lamp locking screws.
Tab
Notes and Precautions
The [
Lamp time
] item in the
Status display
menu indicates the time of lamp use. (Use
it as a rough estimate or guide for lamp life.)
p.45
Please replace the lamp after 000 hours of use if [
Lamp power
] in the
Default setting
1
menu is set to [
Standard
], or after 000 hours of use if [
Lamp power
] in the
Default
setting 1
menu is set to [
Low
].
p.42
There may be cases where the lamp stops working before the above mentioned period
expires or before the replacement message is displayed.
Attach the outer lamp cover correctly so that it is secure and not loose. If it is not
attached correctly, the projector may fail to turn on or the lamp may fail to come on.
Always replace the lamp with a new one.
The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang
it, or scratch it. Since dirt, jolts, scratches and other similar particles may affect the lamp.
About lamp replacement messages
The lamp replacement message displays an appropriate period based on the
use period selected in [
Lamp power
].
When the replacement time approaches,
“The lamp life is ending. Please
change the lamp.”
message is displayed each time the power is turned on. The
display disappears when you press the button.
•
•
Used Lamps
This projector’s lamp contains trace amounts of environmentally harmful inorganic
mercury. Be careful not to break used lamps, and dispose of them in accordance with
local regulations.
•
•
•
•
•
•
Lamp replacement (Continued)
7
Replace the inner lamp cover.
Replace and tighten the screws removed in step
4
until
the inner lamp cover is secure.
8
Replace the outer lamp cover.
Align the cover and slide in the direction of the arrow,
then tighten the screw loosened in step
3
until the
outer lamp cover is secure. Always replace the outer
lamp cover.
9
Reset the lamp time.
See the lamp’s manual for instructions on resetting
the lamp time.
Outer lamp cover
Inner lamp cover
1
Unplug power cord.
2
Wait until lamp is sufficiently cooled.
Wait for at least 1 hour.
3
Remove the outer lamp cover.
Loosen the screw attached on the side of the
outer lamp cover. Remove the cover by sliding it
in the direction of the arrow.
4
Remove the inner lamp cover.
Remove the screws and carefully set them aside,
and remove the inner lamp cover. Be sure not to
loose the screws.
Inner lamp cover
Outer lamp cover
Содержание TLP-WX200
Страница 53: ......