Installation
Step 11: Configure Stratagy Flash
18
Stratagy Flash Installation Guide 02/02
Stratagy System Configuration
Use this function to change Stratagy Flash’s system options and parameters, and define time-out
values. Most Stratagy System Configuration options do not require modification.
We recommend that you modify the system password immediately. All other options have default
values, but can be modified as required.
Configure Stratagy Flash Software
1. From the Tools menu, press
6
. The system configuration file displays. The parameters are
listed in alphabetical order.
Note
AMIS, fax, future delivery, and guest settings are not available to the Stratagy Flash.
2. Make changes to the parameters. See “System Configuration”
in Chapter 3 – Configure
Stratagy of the Stratagy R3 I&M Manual for instructions on changing the parameters.
3. Press
ESC
.
4. From the Stratagy System Config screen, press
1.
The changes are transmitted to
Stratagy Flash and Stratagy Flash is shut down and restarted. By shutting down and restarting
Stratagy Flash, the changes take effect.
...or
2
. The changes are transmitted to Stratagy Flash but Stratagy Flash is not shut down or
restarted. Until you restart Stratagy Flash, the changes do not take effect.
...or
3
. The changes you made are cancelled and not saved.
5. If you pressed
1
to save the changes, press any key to reboot. The DOS prompt displays. To
continue, you must re-enter Stratagy Admin.
Table 2
Stratagy Flash System Configuration Parameters – Definitions and Settings
Parameter
Description
accept_0_calling_id
Specifies whether Stratagy should accept 0 as valid mailbox number. If the
parameter is set to “false,” SMDI packets that include 0 for the “forwarding from
station number” (forwarded call SMDI packets) or for the “calling station number”
(direct call SMDI packet) are not accepted.
Possible values:
false (mailbox 0 not accepted), true (mailbox 0 accepted)
Default:
false
admin_port
Defines the logical port that Stratagy Flash software uses. In order for Stratagy Flash
to communicate with the Stratagy Admin PC connected to one of its serial ports,
Stratagy Flash needs to know which port will be used.
Example:
Set this parameter to 1 for logical serial port 1.
CAUTION!
The connection will fail if the baud parameter for this port is set
higher than 9600 or the serial port definitions for this port do not
correspond to the definitions for the COM port being used on the
Stratagy Admin PC.
Possible values:
1 (COM1), 2 (COM2)
Default:
2