background image

– 1 –

Compact 4-way Type

Owner’s Manual

Compact 4-way Type

Owner’s Manual

Original instruction

Contents

1 Precautions for Safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

2 Part Names  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

3 Wired Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

4 Correct Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6

5 Timer Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

6 Adjustment of Wind Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8

7 Power Saving Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9

8 Self Clean Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10

9 Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

11 Operations and Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

12 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

13 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

ADOPTION OF NEW REFRIGERANT

This Air Conditioner uses R410A an environmentally friendly refrigerant.

This appliance is not intended for use by person (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety.

Thank you for purchasing this Toshiba air conditioner.

 

Please read carefully through these instructions that contain important information which complies with the “Machinery” 
Directive (Directive 2006 / 42 / EC), and ensure that you understand them.

 

After reading these instructions, be sure to keep them in a safe place together with the Owner’s Manual and Installation Manual 
supplied with your product.

Generic Denomination: Air Conditioner

Definition of Qualified Installer or Qualified Service Person

The air conditioner must be installed, maintained, repaired and removed by a qualified installer or qualified service person. 
When any of these jobs is to be done, ask a qualified installer or qualified service person to do them for you.

 

A qualified installer or qualified service person is an agent who has the qualifications and knowledge described in the table 
below.

Agent

Qualifications and knowledge which the agent must have

 Qualified installer

• The qualified installer is a person who installs, maintains, relocates and removes the air conditioners made 

by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and remove the air 
conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such 
operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the 
knowledge related to these operations.

• The qualified installer who is allowed to do the electrical work involved in installation, relocation and removal 

has the qualifications pertaining to this electrical work as stipulated by the local laws and regulations, and 
he or she is a person who has been trained in matters relating to electrical work on the air conditioners made 
by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an 
individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge 
related to this work.

• The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation, 

relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as 
stipulated by the local laws and regulations, and he or she is a person who has been trained in matters 
relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation 
or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been 
trained and is thus thoroughly acquainted with the knowledge related to this work.

• The qualified installer who is allowed to work at heights has been trained in matters relating to working at 

heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been 
instructed in such matters by an individual or individuals who have been trained and is thus thoroughly 
acquainted with the knowledge related to this work.

Qualified service 
person

• The qualified service person is a person who installs, repairs, maintains, relocates and removes the air 

conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, repair, maintain, 
relocate and remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she 
has been instructed in such operations by an individual or individuals who have been trained and is thus 
thoroughly acquainted with the knowledge related to these operations.

• The qualified service person who is allowed to do the electrical work involved in installation, repair, 

relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws 
and regulations, and he or she is a person who has been trained in matters relating to electrical work on the 
air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such 
matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the 
knowledge related to this work.

• The qualified service person who is allowed to do the refrigerant handling and piping work involved in 

installation, repair, relocation and removal has the qualifications pertaining to this refrigerant handling and 
piping work as stipulated by the local laws and regulations, and he or she is a person who has been trained 
in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier 
Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals 
who have been trained and is thus thoroughly acquainted with the knowledge related to this work.

• The qualified service person who is allowed to work at heights has been trained in matters relating to 

working at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she 
has been instructed in such matters by an individual or individuals who have been trained and is thus 
thoroughly acquainted with the knowledge related to this work.

1-EN

2-EN

+00EH99937799_01EN.book  Page 1  Thursday, March 31, 2011  10:00 PM

Содержание RAV-SM404MUT-E

Страница 1: ...s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Compact 4 way Type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E 00EH99937799_01EN book Page 1 Thursday March 31 2011 10 00 PM ...

Страница 2: ...tallation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an indi...

Страница 3: ...l work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker ...

Страница 4: ... ON position until the improvements or refitting is completed Do not customize the unit Doing so may result in fire electric shock or other trouble Relocation When the air conditioner is to be relocated do not relocate it yourself but contact a qualified installer or a qualified service person Failure to relocate the air conditioner properly may result in electric shocks and or a fire CAUTION To d...

Страница 5: ... notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air f...

Страница 6: ...to save energy SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 20 11 14 13 12 18 8 7 Auto High Med Low 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used...

Страница 7: ... on the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Prepara...

Страница 8: ...ailable during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe prope...

Страница 9: ...peration The louver direction changes for every push of the button In HEAT operation Direct the louver adjustment plate of up down wind direction downward If directing at horizontally hot air may not come to the foot In COOL DRY operation Direct the louver adjustment plate of up down wind direction horizontally If directing it downward the dew may form on the surface of the air discharge port and ...

Страница 10: ...de The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled To cancel the power saving mode push button again disappears To configure the power saving mode sett...

Страница 11: ...in power saving mode 8 Self Clean Mode This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling dry AUTO cooling mode to keep the indoor unit clean The self clean time varies with the cooling dry Auto cooling operation time as follows is displayed on the remote controller during self clean operation To stop self clean forcibly push button twice ...

Страница 12: ...mmended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general...

Страница 13: ...xpands and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote control...

Страница 14: ... proper performance operate the air conditioner under the following temperature conditions If air conditioner is used outside of the above conditions safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess o...

Страница 15: ...rized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Cond...

Страница 16: ...ORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99937799_01EN book Page 33 Thursday March 31 2011 10 00 PM ...