• Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner, otherwise 

it may cause imperfect combustion.

• When the air conditioner is operated with a combustion appliance in the same place, ventilate the room sufficiently. 

Poor ventilation causes oxygen shortage.

• When the air conditioner is used in a closed room, sufficiently ventilate the room. Poor ventilation causes oxygen 

shortage.

• Do not expose your body to cool air directly for a long time and do not cool yourself excessively.

 

Doing so may result in deteriorated physical condition and ill health.

• Do not insert your finger or a stick into the air intake or discharge.

 

Doing so may result injury as the fan is rotating at high speed inside the unit. 

• Consult the shop where you purchased the air conditioner if air conditioning (cooling and heating) is not performed 

properly as a refrigerant leakage may be the cause. Confirm the repair details with a qualified service person(*1) 
when the repair includes additional charging of the refrigerant. 

• Stop running the air conditioner and turn off the breaker before cleaning.

 

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

Repairs

• If there is any kind of trouble (such as when an error display has appeared, there is a smell of burning, abnormal 

sounds are heard, the air conditioner fails to cool or heat or water is leaking) has occurred in the air conditioner, do 
not touch the air conditioner yourself but set the circuit breaker to the OFF position, and contact a qualified service 
person. Take steps to ensure that the power will not be turned on (by marking “out of service” near the circuit breaker, 
for instance) until qualified service person arrives. Continuing to use the air conditioner in the trouble status may 
cause mechanical problems to escalate or result in electric shocks or other trouble.

• If the fan grille is damaged, do not approach the outdoor unit but set the circuit breaker to the OFF position, and 

contact a qualified service person to have the repairs done. Do not set the circuit breaker to the ON position until the 
repairs are completed.

• If there is a danger of the indoor unit’s falling, do not approach the indoor unit but set the circuit breaker to the OFF 

position, and contact a qualified installer or a qualified service person to refit the unit. Do not set the circuit breaker 
to the ON position until the unit has been refitted.

• If there is a danger of the outdoor unit’s toppling over, do not approach the outdoor unit but set the circuit breaker to 

the OFF position, and contact a qualified installer or a qualified service person to have the improvements or refitting 
done. Do not set the circuit breaker to the ON position until the improvements or refitting is completed.

• Do not customize the unit. Doing so may result in fire, electric shock or other trouble.

Relocation

• When the air conditioner is to be relocated, do not relocate it yourself but contact a qualified installer or a qualified 

service person. Failure to relocate the air conditioner properly may result in electric shocks and / or a fire.

CAUTION

To disconnect the appliance from the mains supply.

• This appliance must be connected to the mains by means of a switch with a contact separation of at least 

3 mm

.

The installation fuse (all types can be used) must be used for the power supply line of this air conditioner.

Installation

• Certainly lay the drain hose for perfect draining. Improper drainage may cause flooding in the house and getting 

furniture wet.

• Connect the air conditioner to an exclusive power supply of the rated voltage, otherwise the unit may break down or 

cause a fire.

• Confirm that the outdoor unit are fixed on the base. Otherwise, falling down of the units or other accidents may occur.

Operation

• Do not use this air conditioner for special purpose such as preserving food, precision instruments, art objects, 

breeding animals, car, vessel.

• Do not touch any switches with wet finger, otherwise you may get an electric shock.
• If the air conditioner will not be used for a considerably long time, turn off the main switch or the circuit breaker, for 

safety.

• To make the air conditioner operate in its original performance, operate it within the range of the operating 

temperature specified in the instructions. Otherwise it may cause a malfunction, or water leak from the unit.

• Prevent any liquid from falling into the remote controller. Do not spill juice, water or any kind of liquid.
• Do not wash the air conditioner. Doing so may result in electric shock.
• Check whether the installation base and other equipment have become deteriorated after being used for a long time. 

Leaving them such condition may result in the unit’s falling down and causing injury. 

• Do not leave flammable sprays or other flammable materials near the air conditioner, and do not spray flammable 

aerosol directly to the air conditioner. They may catch fire.

• Stop running the air conditioner and turn off the breaker before cleaning.

 

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

• Ask for cleaning of the air conditioner to be performed by the dealer.

 

Cleaning the air conditioner in an improper manner may cause damage to plastic parts, insulation failure of electric 
parts or other parts, and result in a malfunction. In the worst case, it may result in water leakage, electric shock, 
smoke emission or fire.

• Do not put a water container such as a vase on the unit.

 

Water intrusion into the unit may occur and it may cause deterioration of electric insulation and result in electric shock.

(*1) Refer to the “Definition of Qualified Installer or Qualified Service Person.”

5-EN

6-EN

+00EH99937799_01EN.book  Page 3  Thursday, March 31, 2011  10:00 PM

Содержание RAV-SM404MUT-E

Страница 1: ...s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Compact 4 way Type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E 00EH99937799_01EN book Page 1 Thursday March 31 2011 10 00 PM ...

Страница 2: ...tallation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an indi...

Страница 3: ...l work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker ...

Страница 4: ... ON position until the improvements or refitting is completed Do not customize the unit Doing so may result in fire electric shock or other trouble Relocation When the air conditioner is to be relocated do not relocate it yourself but contact a qualified installer or a qualified service person Failure to relocate the air conditioner properly may result in electric shocks and or a fire CAUTION To d...

Страница 5: ... notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air f...

Страница 6: ...to save energy SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 20 11 14 13 12 18 8 7 Auto High Med Low 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used...

Страница 7: ... on the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Prepara...

Страница 8: ...ailable during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe prope...

Страница 9: ...peration The louver direction changes for every push of the button In HEAT operation Direct the louver adjustment plate of up down wind direction downward If directing at horizontally hot air may not come to the foot In COOL DRY operation Direct the louver adjustment plate of up down wind direction horizontally If directing it downward the dew may form on the surface of the air discharge port and ...

Страница 10: ...de The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled To cancel the power saving mode push button again disappears To configure the power saving mode sett...

Страница 11: ...in power saving mode 8 Self Clean Mode This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling dry AUTO cooling mode to keep the indoor unit clean The self clean time varies with the cooling dry Auto cooling operation time as follows is displayed on the remote controller during self clean operation To stop self clean forcibly push button twice ...

Страница 12: ...mmended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general...

Страница 13: ...xpands and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote control...

Страница 14: ... proper performance operate the air conditioner under the following temperature conditions If air conditioner is used outside of the above conditions safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess o...

Страница 15: ...rized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Cond...

Страница 16: ...ORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99937799_01EN book Page 33 Thursday March 31 2011 10 00 PM ...

Отзывы: