background image

– 5 –

Compact 4-way Type

Owner’s Manual

Compact 4-way Type

Owner’s Manual

3

Wired Remote Controller

This remote controller can control the operation of up to 8 indoor units.

„

Display section

In the display illustration below all the icons are shown. When the unit is in operation, 
only relevant icons will be displayed.   
• When the leak breaker is turned on for the first time, 

 flashes on the display 

part of the remote controller. 

• While this icon is flashing, the model is being automatically confirmed. 

 

Wait till 

 icon has disappeared to use the remote controller.

 

 
 
 

1

Operation mode

The selected operation mode is displayed.

2

Error display

Displayed while the protective device works or a error 
occurs.

3

SETTING display

Displayed during setup of the timer or other settings.

4

TEST run display

Displayed during a test run.

5

Timer display

When an error occurs, error code is displayed.

6

Timer mode display

The selected timer mode is displayed.

7

Louver position display

Displays louver position.

8

Swing display

Displayed during up / down movement of the louver.

9

Filter display

Reminder to clean the air filter.

10

Fan speed display

The selected fan speed mode is displayed.

11

Set temperature display

The selected set temperature is displayed.

12

Power saving mode display

Limits compressor speed (capacity) to save energy.

SET

TIME

TIMER SET

TEST

FILTER

RESET

TEMP.

CL

FAN

SAVE

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

Display 
section

Operation 
section

1

10

6

19

4

2

3

5
9

15

17

16

20

11

14

13

12

18

8

7

(Auto)

(High)

(Med.)

(Low)

13

UNIT No. display

Displays the number of the indoor unit selected.

 

Also displays error code of indoor and outdoor units.

14

Central control display

Displayed when the air conditioner is used under the 
central control in combination with a central control 
remote controller.

In case the remote controller is disabled by the central 
control system, 

 flashes.

 

The button operation is not accepted. 

Even when ON / OFF, MODE, or TEMP. button is 
pushed, and the button operation is not accepted. 

 

(Settings made by the remote controller vary with the 
central control mode. For details, refer to the Owner’s 
Manual of the central control remote controller.)

15

Remote controller sensor display

Displayed while the sensor of the remote controller is 
used.

16

Pre-heat display

Displayed when the heating mode is energized or 
defrost cycle is initiated.
While this icon is displayed, the indoor fan stops.

17

No function display

Displayed when the function requested is not available 
on that model.

18

Self clean operation display

Displayed during self clean operation to dry the indoor 
heat exchanger.

19

Service display

20

Operation ready display

This display appears on some models.

1

6

4

2

3

5
9

15

17

16

11

14

13

12

10

19

20

18

8

7

9-EN

10-EN

+00EH99937799_01EN.book  Page 5  Thursday, March 31, 2011  10:00 PM

Содержание RAV-SM404MUT-E

Страница 1: ...s Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Compact 4 way Type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E 00EH99937799_01EN book Page 1 Thursday March 31 2011 10 00 PM ...

Страница 2: ...tallation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an indi...

Страница 3: ...l work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker ...

Страница 4: ... ON position until the improvements or refitting is completed Do not customize the unit Doing so may result in fire electric shock or other trouble Relocation When the air conditioner is to be relocated do not relocate it yourself but contact a qualified installer or a qualified service person Failure to relocate the air conditioner properly may result in electric shocks and or a fire CAUTION To d...

Страница 5: ... notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air f...

Страница 6: ...to save energy SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER Display section Operation section 1 10 6 19 4 2 3 5 9 15 17 16 20 11 14 13 12 18 8 7 Auto High Med Low 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control display Displayed when the air conditioner is used...

Страница 7: ... on the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Prepara...

Страница 8: ...ailable during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe prope...

Страница 9: ...peration The louver direction changes for every push of the button In HEAT operation Direct the louver adjustment plate of up down wind direction downward If directing at horizontally hot air may not come to the foot In COOL DRY operation Direct the louver adjustment plate of up down wind direction horizontally If directing it downward the dew may form on the surface of the air discharge port and ...

Страница 10: ...de The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled To cancel the power saving mode push button again disappears To configure the power saving mode sett...

Страница 11: ...in power saving mode 8 Self Clean Mode This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling dry AUTO cooling mode to keep the indoor unit clean The self clean time varies with the cooling dry Auto cooling operation time as follows is displayed on the remote controller during self clean operation To stop self clean forcibly push button twice ...

Страница 12: ...mmended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general...

Страница 13: ...xpands and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote control...

Страница 14: ... proper performance operate the air conditioner under the following temperature conditions If air conditioner is used outside of the above conditions safety protection may work Cooling operation Outdoor temperature 15 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess o...

Страница 15: ...rized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM404MUT E RAV SM454MUT E RAV SM564MUT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Cond...

Страница 16: ...ORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99937799_01EN book Page 33 Thursday March 31 2011 10 00 PM ...