<Wireless remote controller>
Wireless remote controller A-B selection
Using 2 wireless remote controllers for the respective air conditioners, when the 2 air conditioners are closely
installed. Address (A-B selection) must be changed on both signal receiving unit and wireless remote controller.
Wireless remote controller B setup
1.
Push the START/STOP button to operate the air conditioner. Push it again to stop the air conditioner.
2.
Push [Temporary] button on the signal receiving unit to operate the air conditioner.
3.
Point the wireless remote controller at the indoor unit.
4.
Push and hold
CHK
button on the wireless remote controller by the tip of the pencil. “
00
” will be shown on
the display.
5.
Push the MODE button during pushing
CHK
.
“B” will be shown on the display and “
00
” will be disappear and the air conditioner will turn OFF. The
wireless remote controller B is memorized.
Note:
• Repeat above step to reset wireless remote controller to be A.
• The wireless remote controllers do not display “A”.
• The factory default of the wireless remote controllers is “A”.
SWING
FAN
FIX
QUIET
Hi POWER
COMFORT
SLEEP
1
5
4
“B” Display
“00” Display
- 84 -