Thank you for purchasing this air conditioner.
Please read carefully through these instructions that contain important information which complies with the
Machinery Directive (Directive 2006/42/EC), and ensure that you understand them.
After completing the installation work, hand over this Installation Manual as well as the Owner’s Manual provided
to the user, and ask the user to keep them in a safe place for future reference.

Generic Denomination: Air Conditioner

De

fi

nition of Quali

fi

ed Installer or Quali

fi

ed Service Person

The air conditioner must be installed, maintained, repaired and removed by a quali

fi

ed installer or quali

fi

ed service 

person. When any of these jobs is to be done, ask a quali

fi

ed installer or quali

fi

ed service person to do them for you. 

A quali

fi

ed installer or quali

fi

ed service person is an agent who has the quali

fi

cations and knowledge described in 

the following table.

Agent

Quali

fi

cations and knowledge which the agent must have

Quali

fi

ed installer

• The quali

fi

ed installer is a person who installs, maintains, relocates and removes the air conditioners 

made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and 
remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been
instructed in such operations by an individual or individuals who have been trained and is thus 
thoroughly acquainted with the knowledge related to these operations.

• The quali

fi

ed installer who is allowed to do the electrical work involved in installation, relocation and

removal has the quali

fi

cations pertaining to this electrical work as stipulated by the local laws and

regulations, and he or she is a person who has been trained in matters relating to electrical work on
the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been 
instructed in such matters by an individual or individuals who have been trained and is thus thoroughly
acquainted with the knowledge related to this work.

• The quali

fi

ed installer who is allowed to do the refrigerant handling and piping work involved in 

installation, relocation and removal has the quali

fi

cations pertaining to this refrigerant handling and 

piping work as stipulated by the local laws and regulations, and he or she is a person who has been 
trained in matters relating to refrigerant handling and piping work on the air conditioners made by 
Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an 
individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge 
related to this work.

•  The quali

fi

ed installer who is allowed to work at heights has been trained in matters relating to working

at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she 
has been instructed in such matters by an individual or individuals who have been trained and is thus 
thoroughly acquainted with the knowledge related to this work.

Quali

fi

ed service 

person

• The quali

fi

ed service person is a person who installs, repairs, maintains, relocates and removes the

air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, repair,
maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or, 
alternatively, he or she has been instructed in such operations by an individual or individuals who have
been trained and is thus thoroughly acquainted with the knowledge related to these operations.

• The quali

fi

ed service person who is allowed to do the electrical work involved in installation, repair, 

relocation and removal has the quali

fi

cations pertaining to this electrical work as stipulated by the local

laws and regulations, and he or she is a person who has been trained in matters relating to electrical 
work on the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been
instructed in such matters by an individual or individuals who have been trained and is thus thoroughly
acquainted with the knowledge related to this work.

• The quali

fi

ed service person who is allowed to do the refrigerant handling and piping work involved in 

installation, repair, relocation and removal has the quali

fi

cations pertaining to this refrigerant handling 

and piping work as stipulated by the local laws and regulations, and he or she is a person who has 
been trained in matters relating to refrigerant handling and piping work on the air conditioners made 
by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an 
individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge 
related to this work.

• The quali

fi

ed service person who is allowed to work at heights has been trained in matters relating to 

working at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he 
or she has been instructed in such matters by an individual or individuals who have been trained and 
is thus thoroughly acquainted with the knowledge related to this work.

De

fi

nition of Protective Gear

When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves 
and ‘safety’ work clothing.
In addition to such normal protective gear, wear the protective gear described below when undertaking the special 
work detailed in the following table.
Failure to wear the proper protective gear is dangerous because you will be more susceptible to injury, burns, 
electric shocks and other injuries.

Work undertaken

Protective gear worn

All types of work

Protective gloves
‘Safety’ working clothing

Electrical-related
work

Gloves to provide protection for electricians and from heat
Insulating shoes 
Clothing to provide protection from electric shock

Work done at heights 
(50 cm or more)

Helmets for use in industry

Transportation of heavy 
objects

Shoes with additional protective toe cap

Repair of outdoor unit

Gloves to provide protection for electricians and from heat

These safety cautions describe important matters concerning safety to prevent injury to users or other people 
and damages to property. Please read through this manual after understanding the contents below (meanings of 
indications), and be sure to follow the description.

Indication

Meaning of Indication

 

WARNING

Text set off in this manner indicates that failure to adhere to the directions in the warning 
could result in serious bodily harm (*1) or loss of life if the product is handled improperly.

 

CAUTION

Text set off in this manner indicates that failure to adhere to the directions in the caution 
could result in slight injury (*2) or damage (*3) to property if the product is handled 
improperly.

*1:  Serious bodily harm indicates loss of eyesight, injury, burns, electric shock, bone fracture, 

poisoning, and other injuries which leave aftereffect and require hospitalization or long-term 
treatment as an outpatient.

*2:  Slight injury indicates injury, burns, electric shock, and other injuries which do not require 

hospitalization or longterm treatment as an outpatient.

*3:  Damage to property indicates damage extending to buildings, household effects, domestic 

livestock, and pets.

MEANINGS OF SYMBOLS DISPLAYED ON THE UNIT

WARNING

(Risk of 

fi

re)

This mark is for R32 refrigerant only. 
In case that refrigerant type is R32, this unit uses a 

fl

ammable 

refrigerant.
If refrigerant leaks and comes in contact with 

fi

re or heating part, it will 

create harmful gas and there is risk of 

fi

re.

Read the OWNER’S MANUAL carefully before operation.

Service personnel are required to carefully read the OWNER’S MANUAL and INSTALLATION 
MANUAL before operation.

Further information is available in the OWNER’S MANUAL, INSTALLATION MANUAL, and 
the like.

Содержание RAV-HM1101UTP-E

Страница 1: ...NDITIONER SPLIT TYPE Installation Manual Indoor Unit Model name For commercial use English R32 RAV HM561UTP E RAV HM801UTP E RAV HM901UTP E RAV HM1101UTP E RAV HM1401UTP E RAV HM1601UTP E 4 way Cassette type ...

Страница 2: ...rigerant HFC R32 which does not destroy the ozone layer Be sure to check the refrigerant type for outdoor unit to be combined and then install it Product information of ecodesign requirements Regulation EU 2016 2281 http ecodesign toshiba airconditioning eu en Please read this Installation Manual carefully before installing the Air Conditioner This Manual describes the installation method of the i...

Страница 3: ... person who has been trained in matters relating to electrical work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified service person who is allowed to do the refrigerant handling and pi...

Страница 4: ... breaker to the OFF position Otherwise electric shocks may result Place a Work in progress sign near the circuit breaker while the installation maintenance repair or removal work is being carried out There is a danger of electric shocks if the circuit breaker is set to ON by mistake Only a qualified installer 1 or qualified service person 1 is allowed to undertake work at heights using a stand of ...

Страница 5: ... unit This appliance is intended to be used by expert or trained users in shops in light industry or for commercial use by lay persons Selection of installation location When the air conditioner is installed in a small room provide appropriate measures to ensure that the concentration of refrigerant leakage occur in the room does not exceed the critical level Do not install in a location where fla...

Страница 6: ...rry out the electrical work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks To connect the electrical wires repair the electrical parts or undertake other electrical jobs wear gloves to provide protection for electricians and from heat insulating shoe...

Страница 7: ... to turn it off in the event that trouble has occurred in the air conditioner If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person 1 to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed After the installation work follow the Owner s Manual to explain...

Страница 8: ...safety maintenance and check Place where drained water will not cause any problem Avoid installing in the following places Place exposed to air with high salt content seaside area or place exposed to large quantities of sulfide gas hot spring Should the unit be used in these places special protective measures are needed A restaurant kitchen where a lot of oil is used or place near machines in a fa...

Страница 9: ... thick Ceiling height Model Possible installed ceiling height HM56 HM80 Type Up to 3 8 m HM90 HM110 HM140 HM160 Type Up to 4 6 m When the height of the ceiling exceeds the distance of the item Standard 4 way in Table as below the hot air is difficult to reach the floor Therefore it is necessary to change the setup value of the high ceiling switch or discharge direction The high ceiling setting is ...

Страница 10: ...n After the location of the indoor unit installation has been determined open the ceiling and install hanging bolts The dimensions of the ceiling opening and hanging bolt pitches are given in the outline drawing and the attached installation pattern When a ceiling already exists lay the drain pipe refrigerant pipe indoor unit outdoor unit connection wires and remote controller wires to their conne...

Страница 11: ...el according to Installation Manual attached with it after piping wiring work has completed Check that installation of indoor unit and ceiling opening part is correct and then install it REQUIREMENT Joint the connecting sections of ceiling panel ceiling surface ceiling panel and indoor unit closely Any gap between them will cause air leakage and the generate condensation or water leakage Remove th...

Страница 12: ...ply a heat insulation so as not to cause a dew dropping Inappropriate piping work may result in water leakage in the room and wet of furniture Piping Heat insulating material Require the following materials for piping and heat insulating at site Piping Hard vinyl chloride pipe VP25 Outer dia Ø32 mm Heat insulator Foam polyethylene Thickness 10 mm or more Flexible hose Use the attached flexible hos...

Страница 13: ...f check by pulling out the float switch connector be sure to return the connector to the original position 1 2 Power terminals CN34 RED Black Red White Black Pull out connector CN34 Red from P C board Single phase 220 240V Perform heat insulating As shown in the figure cover the flexible hose and hose band with the attached heat insulator up to the bottom of the indoor unit without gap Cover the d...

Страница 14: ...e pipe with the attached heat insulator without any gap between the indoor unit The seam must be faced upward ceiling side Flare nut Indoor unit Heat insulation pipe Accessory Banding band locally procured Heat insulator of the pipe Union 7 Electrical connection WARNING Use the specified wires for wiring connect the terminals Securely fix them to prevent external forces applied to the terminals fr...

Страница 15: ...for each indoor unit in the simultaneous twin simultaneous triple and simultaneous double twin systems Wiring diagram Single system Simultaneous twin system Simultaneous triple and double twin system Communication type TU2C Link can be used with these models If the indoor unit and the connected remote controller remote sensor are all TU2C Link models TU2C Link communication will be performed autom...

Страница 16: ... 2 3 A B Heat insulation to wiring connecting port Adhered surface Notched section Power supply terminal block Cord clamp Remote controller terminal block Side D Space 8 5 mm Select side C or D for the power cable clamping position referring to the following table according to the cable type and diameter Cable clamp can be attached on either right or left side When twin system are connected clamp ...

Страница 17: ...until the remote controller becomes available Approx 1 minutes SETTING flashes SETTING goes out Remote controller is available Power on Normal settings were made when the indoor unit was shipped from factory Change the indoor unit settings as required Use the wired remote controller to change the settings The settings cannot be changed using the wireless remote controller sub remote controller or ...

Страница 18: ...re 5 1 0001 2 0002 3 0003 5 0005 4 0004 SET DATA When 4 or 5 is selected dew drop may occur during cooling mode y When the setting has been determined lights up Installing indoor unit on high ceiling When an indoor unit is installed on a ceiling higher than the standard height make the high ceiling setting for fan speed adjustment Follow to the basic operation procedure 1 2 3 4 5 6 For the CODE No...

Страница 19: ...emote controller sensor 0000 Not in use Factory default 0001 In use When flashes the remote controller sensor is defective Select the set data 0000 not in use or replace the remote controller Communication type When connecting to the central control device dedicated to TCC Link it is necessary to change to TCC Link Follow to the basic opreration procedure 1 2 3 4 5 6 7 y Specify FC for the Code No...

Страница 20: ...m setup Example of address setup change After setup of automatic address After setup change of manual address The above address is set by the automatic addressing when the power is turned on However line addresses and indoor addresses are set randomly For this reason change the setting to match line addresses with indoor addresses Manual address setting 1 Push and hold menu button and setting butt...

Страница 21: ...es 4 5 4 5 Indicators Operation green Timer green and Ready orange in the wireless receiver section flash in approx 10 seconds and the air conditioner starts operation If any of these indicators does not flash repeat procedures 2 to 5 7 Upon completion of the test run push ON OFF button to stop operation Overview of test run operations using the wireless remote controller T Cooling test run ON OFF...

Страница 22: ...nger It may differ from the actual discharge temperature 2 For outdoor unit data refer to the Installation Manual and Service Manual of the outdoor unit 10Maintenance CAUTION Before maintenance be sure to turn off the leakage breaker Cleaning of air filter Clogging of the air filter reduce cooling heating performance Cleaning of panel and air filter Preparation 1 Turn off the air conditioner by th...

Страница 23: ...s the owner s expense Failure to clean the indoor and outdoor units regularly will result in poor performance freezing water leakage and even compressor failure Inspection before maintenance Following inspection must be carried out by a qualified installer or qualified service person Parts Possible installed ceiling height Heat exchanger Access from inspection opening and remove the access panel E...

Страница 24: ...short circuit of the heat exchanger sensor TC was detected Auto reset F04 ALT Outdoor unit discharge temp sensor TD error Outdoor Outdoor temp sensor TD outdoor P C board Open circuit or short circuit of the discharge temp sensor was detected Entire stop F06 ALT Outdoor unit temp sensor TE TS error Outdoor Outdoor temp sensors TE TS outdoor P C board Open circuit or short circuit of the heat excha...

Страница 25: ...stop due to incorrect external input into CN80 Entire stop L31 SIM Phase sequence error etc Outdoor Power supply phase sequence outdoor unit P C board Abnormal phase sequence of the 3 phase power supply Operation continued thermost at OFF P01 ALT Indoor unit fan error Indoor Indoor fan motor indoor P C board Indoor AC fan error fan motor thermal relay activated was detected Entire stop P03 ALT Out...

Страница 26: ...Place Issued Masaru Takeyama GM Quality Assurance Dept 5 April 2022 Thailand NOTE This declaration becomes invalid if technical or operational modifi cations are introduced without the manufacturer s consent Declaration of Conformity Manufacturer Toshiba Carrier Thailand Co Ltd 144 9 Moo 5 Bangkadi Industrial Park Tivanon road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand TCF holder TOSH...

Страница 27: ...ity of residue shiny metal dust or other wear residue or mixture of foreign matter is observed trouble will occur 8 When temporary installation and removal of the air conditioner are repeated such as when leased etc 9 If the type of refrigerator oil of the existing air conditioner is other than the following oil Mineral oil Suniso Freol S MS Synthetic oil alkyl benzene HAB Barrel freeze ester seri...

Страница 28: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1115350191 ...

Отзывы: