10-5-
2
.
Power Supply and Connecting Cable Connection
2
1
3
L
N
Connecting
cable
Connecting cable
connect to terminal
block (1, 2, 3, )
Power supply
terminal block
(L, N, )
Power cord
Terminal block
1
2
3
L
Power Supply Input at Outdoor Unit Terminal Block (Recommend)
Indoor Unit
Outdoor Unit
Connecting cable
connect to
1
Terminal block (L N 1 2 3)
Earth line
Connecting cable
Connecting cable
Stripping length of the
connecting cable
3
2
1
Earth line
50 mm
10 mm
70 mm
10 mm
Connecting cable
Earth line
Earth line
Power cord
Power Supply Input at Indoor Unit Terminal Block (Optional)
Indoor Unit
Outdoor Unit
Power supply cable
connect
to
N
t
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Power supply cable
Stripping length of the power
supply cable
N
L
Earth line
50 mm
10 mm
70 mm
10 mm
Connecting cable
Earth line
Connecting cable
Connecting cable
connect to
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Connecting
cable
Earth line
Earth line
Stripping length of the
connecting cable
3
50 mm
10 mm
70 mm
10 mm
Connecting cable
Connecting cable connect to
terminal block (1, 2, 3, )
Terminal block
1
2
3
L
N
2
3
- 75 -