6-1. Indoor Unit
6-2. Outdoor Unit
6. SPECIFICATIONS OF ELECTRICAL PARTS
No.
Type name
Specifications
1 Compressor
RAS-
25
DX136A1T-40N
3-Phases (
4
-Poles) ;
1100
W
2 Fan Motor
WDF-340-A43-1
DC 140-340V ; 43W
3 Pulse Modulating Valve (PMV) coil
CAM-MD12TCTH-5
DC 12V
4
4-Way valve coil
5 Reactor
CH-69-Z-T
L = 19mH, 10A
6 Suction temp. sensor
(TS sensor)
(Inverter attached)
10kΩ at 25°C
7 Discharge temp. sensor
(TD sensor)
(Inverter attached)
62kΩ at 20°C
8 Outside air temp. sensor
(TO sensor)
(Inverter attached)
9 Heat Exchanger temp. sensor
(TE sensor)
(Inverter attached)
10kΩ at 25°C
10 Terminal block
(
6
poles)
JX
0
-
6
B
AC 250V,
3
0A
Parts name
10kΩ at 25°C
STF-H01AJ1872A1
AC 220-240V
No.
Type name
Specifications
1
Fan Motor (for indoor)
2
Room temp. sensor (TA-sensor)
(-)
10kΩ at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
(-)
10kΩ at 25°C
Louver motor
24BYJ48-ST
Output (Rated) 4 phase, DC12V
Parts name
ICF-340-30-6
DC
340
V, 42W
4
RAS-
35
DX151A1T-30N
3-Phases (
4
-Poles) ;
1100
W
- 19 -