No.
Part name
Procedures
Remarks
Drain pan
assembly
1) Follow the procedure item 3 .
2) Remove screw holding the electric part cover.
3) Disconnect the louver motor connector (5P)
from P.C. board assembly.
4) Remove fixing screws of the unit display
and remove unit display.
7
5) Remove the drain pan from the back body.
Louver motor
connector
P.C.board
<To re-installation>
- Press the drain pan into the back body
- Please make sure ribs of drain pan in left
and right side must be install to lock position.
- Press the center arm of drain pan to back
body.
Connectors
Electric part cover
Screw
Unit display
Screw
Louver motor
connector
Center arm
of drain pan
Back body
Drain pan
Back body
Drain pan
Rib of drain pan
Center arm
of drain pan
Back body
Back body
Drain pan
Rib of drain pan
- 108 -