Item
Operation flow and applicable data, etc.
Description
18. Hi-POWER ([Hi-POWER] button on the remote controller
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto or cooling operation, Hi-POWER mark
.
Mode
is indicated on the display of the remote controller and
the unit operates as follows.
1. Automatic operation
•
The indoor unit operates in according to the
current operation.
2. Cooling operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
•
The preset temperature drops 1ºC [2°F]
(The value of the preset temperature on the
3. The Hi-POWER mode can not be set in Dry
operation
−
40
−
FILE NO. SVM-13074
17. One-Touch
Comfort
One touch comfort is the fully automated operation
that is set according to the preferable condition in
a region.
0
12
25
* Hi-POWER/
Fan
Operation
Time after operation
starts (min)
*Hi-POWER/AUTO: Fan operates depends on the
setting temperature and room temperature.
During the One Touch Comfort mode if the indoor
unit receives any signal with other operation mode,
the unit will cancel the comfort mode and operates
according to the signal received.
AUTO
Hi-POWER
AUTO
.
When an indoor unit receives "One Touch
Comfort Signal" from the remote controller,
the indoor unit operates as following.
1) Air conditioner starts to operation when
the signal is received, even if the air
conditioner was OFF.
2) Target temperature is 22ºC [72°F].
3) Louver position is set as swing position.
4) Fan is controlled as followings.
Содержание RAS-17EACV-UL
Страница 19: ...FILE NO SVM 13074 19 5 WIRING DIAGRAM ...