FILE NO. SVM-13074
10-
4
-2. Cutting a Hole and Mounting the
mounting Plate
Cutting a hole
When installing the refrigerant pipes from the rear.
Fig. 10-4-1
CAUTION
10-
4
. Indoor Unit
10-
4
-1. Installation Location
• A location which provides
clearances around the
indoor unit as shown in the diagram in the
"CLEARANCES" section.
•
A location where there are no obstacles near the
air inlet and outlet.
•
A location which allows easy installation of the piping
to the outdoor unit.
•
A location which allows the front panel to be opened
•
The indoor unit shall be installed such that the top
unit.
of the indoor unit comes to at least 6.6 ft (2 m) height.
Also avoid putting anything on the top of the indoor
CAUTION
• Direct sunlight on the indoor unit
's
wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to RF noise sources.
(For details, see the owner's manual.)
After determining the pipe hole position on the
mounting plate (
ð
), drill the pipe hole
∅
2-9/16 in.
(
∅
65 mm) at a slight downward slant to the outdoor
side.
NOTE :
• When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the mounting plate
Fig.
10
-
4
-2
When the installat
ing
plate is directly
mounted
to
the wall
1.
To hook up the indoor unit, securely fit the
mounting plate onto the wall by screwing it in the
upper and lower parts.
2. To mount the mounting plate on a concrete wall
with
,
anchor
bolts,
drill the anchor bolt holes as
illustrated in the figure shown below.
3. Make sure the mounting plate is level
ed
.
CAUTION
When installing the mounting plate with a mounting
screw, do not use the anchor bolt holes.
Otherwise, the unit may fall down and result in
personal injury and property damage.
Fig. 10-
4
-3
Anchor bolt
Projection
9/16 in. (15 mm)
Installation plate
(Keep horizontal direction.)
or less
–
54
–
•
A location that will bear the weight of the unit.
m from the right side edge is
e
center of pipe hole
35
120
180
240
The center of the pipe hole is above
the arrow.
Pipe hole
14/16 in.
(23 mm)
Ø2-9/16 in. (65 mm)
To unit out line
240mm
To unit out line
35mm
To unit out line
240mm
Offset 23mm from the right side edge is
the center of pipe hole
To unit out line
120mm
0
23
35
120
180
240
Offset 85mm from the left side edge is
the center of pipe hole
1
7
Anchor bolt holes
Hook
Hook
Hook
Pipe hole
Pipe hole
Ø2-9/16 in.
(Ø65 mm)
Mounting plate
Weight
Indoor unit
Thread
6
.6
f
t
(2
m
)
o
r
m
o
re
fr
o
m
ß
o
o
r
Mounting
Screw
7 in.
(170 mm)
3-11/32 in.
(85 mm)
Ø
2-
9/
16
in
.
(6
5
m
m
)
1 in.
(23 mm)
5 in.
(132 mm)
7 in.
(170 mm)
2
i
n
.
(5
0
m
m
)
1
-1
/2
i
n
.
(4
0
m
m
)