FILE NO. SVM-13074
10-
4
-3. How to connect remote controller for wire operation>
(Optional)
<For indoor unit>
1. Open the air inlet grille upward.
2.
Remove the screws securing the front panel.
3. Slightly open the
l
ower part of the front panel th
e
n
pull the upper part of the front toward you to remove
it from the rear plate as shown
in
figure
1
.
Fig. 10-
4
-9
Fig. 10-
4
-10
Fig. 10-
4
-11
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
70 mm
5 mm
4
<For remote controller>
1. Remove cover of remote controller by sliding down
and taking it out.
2. If batteries are installed, please take them out.
Do not install batteries for hard-wire installation.
3. With the help of a screwdriver hreak the polyester
sheet as shown on figure
7
.
4. Insert control wire from rear side of the remote controller
as shown in figure
8
.
5. With the provided screws, tighten the control wire to the
aremote control terminal as shown in figure
10
(tightening
btorque not to exceed 0.25 N-m (0.03 kgtk-m)) Wire
6. Route the control wire through the gutter way at the rear
side of remote controller as shown on figure
11
.
7. Fix provided screw (
∅
1 3.1 x 16L) to the wall to hang
remote controller as shown in figure
12
.
8. Mark and arrange a hole to fix the battery cover screw
(
∅
3.1 x 25L) as shown in figure
12
.
9. Fix the battery cover to the remote controller and wall
with the provided screw (
∅
3.1 x 25L)
as shown in
figure
13
.
(tighten firmly but not over 0.15 N.m (0.02 kgf.m)).
10. Put back the remote controller cover.
specifications are shown in figure
9
.
Fig. 10-
4
-12
Control wire
30 mm
10 mm
* Wire size 28-22 AWG (0.08~0.32 mm
2
)
Outer diameter not over 4.7 mm,
control wire length
3
0 m. or less.
9
Control wire
Terminal
!
Tighten fi rmly but not over
0.25 N·m (0.03 kgf·m)
7 8
Indoor unit
Control wire
Remote controller
Polyester sheet
WARNING :
Do not install batteries for hard wire installation
EXPLOSION HAZARD
WARNING :
Do not install batteries for hard wire installation
EXPLOSION HAZARD
Air inlet grille
Front panel
1
2
1
3
Control board
2
3
Control board
Remove screw
6
5
Terminal
Control wire
Control wire out position
Control wire through out position
Tighten Þ rmly but
not over 0.12 N·m
(0.01 kgf·m)
Control wire
assembly
4.
After removing the front panel, remove the
screws and
control board assembly from the unit as shown in
figure 2 then open the front cover of control board
assembly as shown in figure 3 .
5. Arrange the control wire as
specified and shown in
figure
4
.
6. Securely connect the control wire to
the
terminal of
the
control board as shown in figure 5
(tighten
firmly but
not
over :
0.12 N·m (0.01 kgf·m).
7.
Route the wire along the bottom of the control board
and through the opening of the casing.
Reassemble the control board assembly.
8.
Route the wire along with the
power supply and
connecting cable as
shown on figure 6 .
9.
Reassemble
the indoor unit by revers
ing
processes
1 to 3.
–
56
–
Содержание RAS-17EACV-UL