Item
15. QUIET mode
Operation flow and applicable data, etc.
Description
When the [QUIET] button is pressed, the fan of the
indoor unit will be restricted the revolving speed at
−
until the [QUIET] button is pressed once
Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less
cooling load condition. Because of the fan
Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.
speed L
again (cancel Quiet mode).
speed L- may cause not enough the cooling
capacity.
16. COMFORT The principles of comfort sleep mode are:
•
Quietness for more comfortable. When
•
Save energy by changing room temperature
•
The air condition can shut down by itself
Remarks:
Comfort sleep mode will not operate in dry
automatically.
mode and fan only mode.
automatically.
room temperature reach setting temperature
Cooling mode
•
The preset temperature will increase as below.
•
Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to select the hours.
•
If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
(1hr, 3hr, 5hr or 9hr)
.
−
39
−
SLEEP
FILE NO. SVM-13074
Hz
15EKCV-UL
17EKCV-UL
Cool min
DRY max
10
49
1
0
50
22EKCV-UL
* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min
* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min
(Room temp. – Set temp.)
6.3
5.5
4.5
2.7
2.0
-2.0
-3.5
10.0
11.0
11.7
9.0
8.0
7.0
3.5
1.0
-1.0
(°C)
°F
during the ECO operation.
(3.5)
(3.0)
(2.5)
(1.5)
(1.0)
TSC
(-1.0)
(-2.0)
(5.5)
1H
2H
11
10
7
6
5
4
3
2
1
OFF
Dry Max
*12
*11
*9
*8
*10
(6.0)
(6.5)
3H
4H
(5.0)
(4.5)
(4.0)
(2.0)
(0.5)
(-0.5)
12
9
8
Time
Zone Frequency
FAN
Min
Hz
The indoor fan speed is not controlled and can be selected
0.0
Содержание RAS-17EACV-UL