background image

English

Operating Instructions

Air Conditioner

Operating Instructions
Air Conditioner

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer 
keep them for future reference.
Remove the remote control packed with the indoor unit.

Model No.
Indoor Unit 

Outdoor Unit

CS-U9XKD-3
CS-U12XKD-3
CS-U18XKD-3

CU-U9XKD-3
CU-U12XKD-3
CU-U18XKD-3

ACXF55-30990

Содержание CS-U9XKD-3

Страница 1: ...s thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the customer keep them for future reference Remove the remote c...

Страница 2: ...ol receiver on the indoor unit Quick Guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press CLOCK then...

Страница 3: ...seconds to show the temperature as C or F 2 Press to select the desired mode DRY iAUTO X COOL Table of Contents Safety Precautions 4 11 How to Use 12 14 To Learn More 15 Cleaning the Air Conditioner 1...

Страница 4: ...nstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant t...

Страница 5: ...for a long period of time New batteries of the same type must be inserted following the polarity stated Power supply Do not disconnect the plug by pulling the cord to prevent electric shock nanoe G ge...

Страница 6: ...l the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of...

Страница 7: ...he precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised a...

Страница 8: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 9: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 10: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 11: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 12: ...ave a low noise operation When iAUTO X mode is selected the fan speed is automatically set to AUTO To adjust the fan speed cancel iAUTO X mode QUIET This operation reduces airflow noise To enjoy fresh...

Страница 13: ...2 C 4 F from the set temperature to accelerate the room cooling effect Fan speed is set to AUTO and you cannot change the fan speed After a maximum of 4 hours the unit returns to the last set tempera...

Страница 14: ...n Press or to select the respective setting or then press The nearest timer setting is displayed and will activate in sequence The timer operation follows the clock setting on the remote control and w...

Страница 15: ...ailure the operation will restart automatically with the last operation mode and airflow direction This control is not applicable when TIMER is set nanoe X filter deactivation Depending on the unit s...

Страница 16: ...ration Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any dama...

Страница 17: ...ials used in plastic parts It is accelerated when exposed to heat sun light UV light or environmental factors After extended use dust may cover the front panel grilles and the wall surrounding the uni...

Страница 18: ...refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents C...

Страница 19: ...r abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mis...

Страница 20: ...attery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WA...